{"id":3759,"date":"2018-01-19T09:21:32","date_gmt":"2018-01-19T09:21:32","guid":{"rendered":"https:\/\/www.mppsolar.com\/v3\/?page_id=3759"},"modified":"2024-02-26T04:25:18","modified_gmt":"2024-02-26T04:25:18","slug":"split-phase-lv","status":"publish","type":"page","link":"https:\/\/www.mppsolar.com\/v3\/split-phase-lv\/","title":{"rendered":"SPLIT PHASE LV SERIES &#8211; LV2424 \/ LV5048 \/ LV6048"},"content":{"rendered":"<h3><\/h3>\n<hr \/>\n<ul class='tabs'><li><a data-href=\"tab-0\" class=\"gdl-title active\" >OVERVIEW<\/a><\/li><li><a data-href=\"tab-1\" class=\"gdl-title \" >FEATURES<\/a><\/li><li><a data-href=\"tab-2\" class=\"gdl-title \" >CATALOGS<\/a><\/li><li><a data-href=\"tab-3\" class=\"gdl-title \" >MONITORING<\/a><\/li><\/ul><ul class='tabs-content'><li data-href=\"tab-0\" class=\"active\" ><p class=\"text\">The Split Phase LV series inverter family features inverters that can support <span style=\"color: #0000ff;\">120V\/240V split phase<\/span> output which is the main power standard used in North American countries including US, Canada, Mexico, and Puerto Rico.\u00a0 Split phase system is defined as having 2 x 120V hot wires (normally denoted as L1 and L2 and each hot wire is 120V in relation to the neutral wire), 1 neutral wire, and a ground wire.\u00a0 By using the two opposite phase hot wires together 240V is created between L1 and L2.<\/p>\n<a href=\"#\" target=\"_self\" class=\"gdl-button shortcode-medium-button\" style=\"color:#000000; background-color:#F2F2F2; border-color:#e6e6e6; \">LV2424<\/a>\n<p>LV2424 is a max 2400w\/24vdc inverter with 110\/120V output and supports both 50Hz or 60Hz frequency.\u00a0 By wiring at least 2 units of LV 2424 parallel, the system can create <span style=\"color: #0000ff;\">split phase<\/span> output, as illustrated below.\u00a0 Parallel kits are required on each unit and sold separately.\u00a0 Maximum parallel operation supported by LV2424 is up to 9 units max and possible configurations include: <span style=\"color: #0000ff;\">single phase, split phase and 3-phase <span style=\"color: #000000;\">applications<\/span><\/span>.\u00a0 <span style=\"color: #800000;\">Note: split phase parallel is limited to 8 units max in total (4 max in each phase)<\/span>.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-3760 aligncenter\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2018\/01\/1-292x300.jpg\" alt=\"\" width=\"292\" height=\"300\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2018\/01\/1-292x300.jpg 292w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2018\/01\/1-600x616.jpg 600w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2018\/01\/1.jpg 602w\" sizes=\"auto, (max-width: 292px) 100vw, 292px\" \/><\/p>\n<a href=\"#\" target=\"_self\" class=\"gdl-button shortcode-medium-button\" style=\"color:#000000; background-color:#F2F2F2; border-color:#e6e6e6; \">LV5048 \/ LV6048<\/a>\n<p><strong>LV6048, rated 6KW\/48V, is a model capable of creating <span style=\"color: #0000ff;\">split phase<\/span> output without the use of parallel.<\/strong>\u00a0 These models can parallel up to 3 units, and from which one can configure system as 3-phase output 208V (phase to neutral).\u00a0 Parallel kits are built-in.\u00a0 LV5048 has been discontinued and replaced by LV6048.<\/p>\n<h3><a href=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2020\/07\/lv5048-outputtype.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-9236\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2020\/07\/lv5048-outputtype.png\" alt=\"\" width=\"961\" height=\"881\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2020\/07\/lv5048-outputtype.png 961w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2020\/07\/lv5048-outputtype-300x275.png 300w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2020\/07\/lv5048-outputtype-768x704.png 768w\" sizes=\"auto, (max-width: 961px) 100vw, 961px\" \/><\/a><\/h3>\n<p class=\"text\">Along with a built-in MPPT solar charger and large utility charger, these split phase LV models offer excellent versatility and flexibility to expand and are ideal for off-grid \/ grid optional use.<\/p>\n<p>For more information, please download the catalogs at the tab page above or contact our sales office at <span style=\"color: #0000ff;\"><a href=\"mailto:sales@mppsolar.com\"><span style=\"color: #0000ff;\">sales@mppsolar.com<\/span><\/a><\/span>.<\/p>\n<\/li><li data-href=\"tab-1\" class=\"\" ><p style=\"color: #ff0000;\"><span style=\"color: #000000;\"><div class=\"shortcode-list shortcode-list-check\"><\/span><\/p>\n<ul>\n<li><strong><span style=\"color: #0000ff;\">Split Phase output possible (120V\/240V), suitable for USA, Canada, Mexico and Puerto Rico markets<\/span><\/strong><\/li>\n<li><strong><span style=\"color: #0000ff;\"><span style=\"color: #ff0000;\">NEW!<\/span> LV6048 (split phase ready): 6KW\/48V output, in 120v single phase \/ 208V, 240V split phase \/ 208V 3-phase <span style=\"color: #000000;\">*parallel kits are built-in.<\/span><\/span><\/strong><\/li>\n<li><strong><span style=\"color: #0000ff;\">LV2424 (120v output).\u00a0 <span style=\"color: #000000;\">*Requires minimum 2 units in parallel to create split phase (120V\/240V), parallel kits sold separately<\/span><\/span><\/strong><\/li>\n<li><strong><span style=\"color: #0000ff;\">Grid Injection feature is available by feeding excess PV power to grid (LV2424 only) &#8212; <span style=\"color: #000000;\">*please check with your local authority for compliance<\/span><\/span><\/strong><\/li>\n<li><strong><span style=\"color: #0000ff;\">Stackable \u2014 parallel up to 9 units (for LV2424), max 3 units for LV5048 \/ LV6048<br \/>\n<\/span><\/strong><\/li>\n<li><strong><span style=\"color: #0000ff;\">Single 80A max MPPT input (LV2424 only)<\/span><\/strong><\/li>\n<li><strong><span style=\"color: #0000ff;\">2X dual MPPT trackers up to 160A combined (LV5048, LV6048 only)<\/span><\/strong><\/li>\n<li><strong><span style=\"color: #0000ff;\">Pure sine wave output<\/span><span style=\"color: #0000ff;\"><br \/>\n<\/span><\/strong><\/li>\n<li><strong><span style=\"color: #0000ff;\">50Hz &amp; 60Hz support<\/span><\/strong><\/li>\n<li>Programmable parameters<\/li>\n<li>Max up to 60A utility charging<\/li>\n<li>Adjustable bulk &amp; float charging voltage<\/li>\n<li>Support either grid or generator input<\/li>\n<li>Genset starter dry contact<\/li>\n<li>Overload and short circuit protection<\/li>\n<li>FREE monitoring software<\/li>\n<li>LCD Display + LED indicators<\/li>\n<li>RS232\/USB communication interface<\/li>\n<\/ul>\n<p><\/div><\/p>\n<div class=\"message-box-wrapper red\"><div class=\"message-box-title\">Using Generator as AC-Input<\/div><div class=\"message-box-content\"><\/p>\n<ul>\n<li>Generator power is recommended to be 50% larger than the inverter rating to reduce chances of overload.<\/li>\n<li>Inverter-generator is recommended due to its cleaner output than conventional generators.\u00a0 Unsuitable generator output may be rejected by the inverter.<\/li>\n<\/ul>\n<p>\n<\/div><\/div>\n<\/li><li data-href=\"tab-2\" class=\"\" ><ul>\n<li><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"http:\/\/www.mppsolar.com\/v3\/catalogs\/split%20phase%20LV6048.pdf\">LV6048 Catalog PDF<\/a><\/span><\/strong><\/li>\n<li><strong><a href=\"http:\/\/www.mppsolar.com\/manual\/SPLIT%20PHASE%20LV\/LV6048%20split%20phase%20manual-20201120.pdf\"><span style=\"color: #0000ff;\">LV6048 user manual<\/span><\/a><\/strong><\/li>\n<li><strong><a href=\"http:\/\/www.mppsolar.com\/v3\/catalogs\/split%20phase%20LV2424.pdf\"><span style=\"color: #0000ff;\">LV2424 Catalog PDF<\/span><\/a><\/strong><\/li>\n<li><strong><a href=\"http:\/\/www.mppsolar.com\/manual\/SPLIT%20PHASE%20LV\/LV2424%20user%20manual-20230915.pdf\"><span style=\"color: #0000ff;\">LV2424 user manual<\/span><\/a><\/strong><\/li>\n<li><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/generator%20requirement.pdf\"><span style=\"color: #0000ff;\">Generator Requirement<\/span><\/a><\/span><\/strong><\/li>\n<\/ul>\n<\/li><li data-href=\"tab-3\" class=\"\" ><ul>\n<li><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"http:\/\/www.mppsolar.com\/manual\/Watchpower%20(off-grid)\/WatchPower%20user%20manual.pdf\">WatchPower Manual (LV6048)`<\/a><\/span><\/strong><\/li>\n<li><strong><a href=\"http:\/\/www.mppsolar.com\/manual\/SolarPower%20%28hybrid%29\/manual\/solarpowermanual.pdf\"><span style=\"color: #0000ff;\">SolarPower Manual (LV2424 only)<\/span><\/a><\/strong><\/li>\n<\/ul>\n<p>**For SolarPower software please contact our Sales team <span style=\"color: #0000ff;\"><a href=\"mailto:sales@mppsolar.com\"><span style=\"color: #0000ff;\">sales@mppsolar.com<\/span><\/a><\/span> directly.<\/p>\n<\/li><\/ul>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-3759","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/3759","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/comments?post=3759"}],"version-history":[{"count":7,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/3759\/revisions"}],"predecessor-version":[{"id":12979,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/3759\/revisions\/12979"}],"wp:attachment":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/media?parent=3759"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}