{"id":3699,"date":"2017-05-01T01:58:31","date_gmt":"2017-05-01T01:58:31","guid":{"rendered":"https:\/\/www.mppsolar.com\/v3\/?page_id=3699"},"modified":"2022-01-03T02:45:28","modified_gmt":"2022-01-03T02:45:28","slug":"pip-hsms-pf1-series","status":"publish","type":"page","link":"https:\/\/www.mppsolar.com\/v3\/pip-hsms-pf1-series\/","title":{"rendered":"PIP-HS\/MS\/MG PF1 Series"},"content":{"rendered":"<h3><span style=\"color: #000080;\">PIP-HS\/MS\/MG PF1 SERIES<\/span><\/h3>\n<hr \/>\n<ul class='tabs'><li><a data-href=\"tab-0\" class=\"gdl-title active\" >OVERVIEW<\/a><\/li><li><a data-href=\"tab-1\" class=\"gdl-title \" >FEATURES<\/a><\/li><li><a data-href=\"tab-2\" class=\"gdl-title \" >CATALOGS<\/a><\/li><li><a data-href=\"tab-3\" class=\"gdl-title \" >VIDEO<\/a><\/li><li><a data-href=\"tab-4\" class=\"gdl-title \" >MONITORING<\/a><\/li><\/ul><ul class='tabs-content'><li data-href=\"tab-0\" class=\"active\" ><p style=\"color: #0000ff;\"><span style=\"color: #000000;\">The new &#8220;<span style=\"color: #0000ff;\">PF1<\/span>&#8221; inverter standards for Power Factor 1.0 version of the <span style=\"color: #0000ff;\">PIP-HS<\/span> and <\/span><span style=\"color: #0000ff;\">PIP-MS<\/span><span style=\"color: #000000;\"> inverter family.\u00a0 All features on the PF1 series are nearly identical to the original PF0.8 models and also retain all the useful functions such as generator starter dry contact and parallel support operation now up to 9 units (only on select 48v models).<br \/>\n<\/span><\/p>\n<p style=\"color: #0000ff;\"><span style=\"color: #000000;\">The new <span style=\"color: #0000ff;\">5048MG<\/span> is a variation model from the 5048MS, with the special added features of <span style=\"color: #0000ff;\">batteryless operation<\/span> and <span style=\"color: #0000ff;\">high PV input voltage (450V)<\/span>, thereby allowing users more flexibility in wider range of application.<\/span><\/p>\n<p style=\"color: #0000ff;\"><span style=\"color: #000000;\"><span style=\"text-decoration: underline;\">It is very important to note that the PF1 versions, despite similarity to the original PF0.8 PIP-HS and PIP-MS inverters, cannot work together in parallel with the PF0.8 models.<\/span> \u00a0 To avoid any confusion, model names have been changed to differentiate.\u00a0 <span style=\"text-decoration: underline;\">All parallel units MUST have the same model name<\/span>.\u00a0<strong>Maximum parallel number of units is now 9<\/strong>, so users can configure a parallel system either as <span style=\"text-decoration: underline;\">single phase or 3-phase, <\/span>(shown below)<\/span><\/p>\n<p style=\"color: #0000ff;\"><a href=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2020\/07\/9pspparallel.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-9173\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2020\/07\/9pspparallel.png\" alt=\"\" width=\"1024\" height=\"241\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2020\/07\/9pspparallel.png 1024w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2020\/07\/9pspparallel-300x71.png 300w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2020\/07\/9pspparallel-768x181.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><a href=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2020\/07\/9p3pparallel.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-9172\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2020\/07\/9p3pparallel.png\" alt=\"\" width=\"1024\" height=\"322\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2020\/07\/9p3pparallel.png 1024w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2020\/07\/9p3pparallel-300x94.png 300w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2020\/07\/9p3pparallel-768x242.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/p>\n<div class=\"message-box-wrapper red\"><div class=\"message-box-title\">Important note about Batteryless Operation<\/div><div class=\"message-box-content\"><p>When configuring system in parallel using multiple units, please be sure that a battery <strong>MUST <\/strong>be used or otherwise it may cause system to work incorrectly, or possibly lead to damage.\u00a0 Due to the inconsistent nature of PV power, batteryless mode can only work normally under single-unit setup.<\/p>\n<\/div><\/div>\n<p style=\"color: #0000ff;\"><span style=\"color: #000000;\">For more information, please download the catalogs at the tab page above or contact our sales office at<\/span> <span style=\"color: #0000ff;\"><a href=\"mailto:sales@mppsolar.com\"><span style=\"color: #0000ff;\">sales@mppsolar.com<\/span><\/a><\/span>.<\/p>\n<\/li><li data-href=\"tab-1\" class=\"\" ><div class=\"shortcode-list shortcode-list-check\"><\/p>\n<ul>\n<li><span style=\"color: #ff0000;\">NEW! Power factor 1.0<br \/>\n<\/span><\/li>\n<li><span style=\"color: #ff0000;\">NEW! Parallel-ready up to 9 units (MS 4-5k, MG only, require parallel kit to work)<\/span><\/li>\n<li><span style=\"color: #ff0000;\">NEW! Equalization up to 64V (MS 4-5k, MG only)<\/span><\/li>\n<li><span style=\"color: #ff0000;\">NEW! Max DC up to 66V (MS 4-5k, MG only)<\/span><\/li>\n<li><span style=\"color: #ff0000;\">NEW! High PV input up to 450V + Batteryless Operation (5048MG only)<\/span><\/li>\n<li><span style=\"color: #ff0000;\">NEW! Bulk charge (C.V.) setting time<br \/>\n<\/span><\/li>\n<li><span style=\"color: #0000ff;\">Available from 1-3KW\/24V and 4-5KW\/48V<\/span><\/li>\n<li>High frequency pure sine wave output, light-weight design<\/li>\n<li>Built-in MPPT and PWM solar chargers<\/li>\n<li>Programmable modes on LCD, e.g. AC priority vs. Solar(DC) priority<\/li>\n<li>Adjustable Bulk\/Float charging voltage<\/li>\n<li>Support lead acid and other batteries<\/li>\n<li>Indoor installation only<\/li>\n<li>3-stage utility battery charger up to 80A<\/li>\n<li>2x surge capacity<\/li>\n<li>Wide AC input ranges<\/li>\n<li>LCD + LED indicators<\/li>\n<li><span style=\"color: #000000;\">FREE monitoring software<\/span><\/li>\n<li><span style=\"color: #000000;\">Built-in generator starter dry-contact<\/span><\/li>\n<\/ul>\n<p><\/div>\n<div class=\"message-box-wrapper red\"><div class=\"message-box-title\">Using Generator as AC-Input<\/div><div class=\"message-box-content\"><\/p>\n<ul>\n<li>Generator power is recommended to be 50% larger than the inverter rating to reduce chances of overload.<\/li>\n<li>Inverter-generator is recommended due to its cleaner output than conventional generators.\u00a0 Unsuitable generator output may be rejected by the inverter.<\/li>\n<\/ul>\n<p>\n<\/div><\/div>\n<\/li><li data-href=\"tab-2\" class=\"\" ><ul>\n<li><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/PIP-HS(PF1).pdf\">PIP-HS (PF1) Series Catalog PDF<\/a><\/span><\/li>\n<li><a href=\"http:\/\/www.mppsolar.com\/v3\/catalogs\/PIP-MS_MG.pdf\"><span style=\"color: #0000ff;\">PIP-MS, PIP-MG 5K (PF1) Series Catalog PDF<\/span><\/a><\/li>\n<li><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/PIP-HS_MS%20Parallel%20Guide.pdf\">PIP-HS\/MS Parallel Guide<\/a><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/generator%20requirement.pdf\">Generator Requirement<\/a><\/span><\/li>\n<\/ul>\n<\/li><li data-href=\"tab-3\" class=\"\" ><p><iframe loading=\"lazy\" title=\"Testing the PIP 4048MS Inverter Charger update  Made by mpp solar inc\" width=\"980\" height=\"551\" src=\"https:\/\/www.youtube.com\/embed\/A5tX0xkYYrc?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe><\/p>\n<p><iframe loading=\"lazy\" title=\"48v Solar off grid system. A look in my power room\" width=\"980\" height=\"551\" src=\"https:\/\/www.youtube.com\/embed\/BQBqLfNU7SY?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe><\/p>\n<p><iframe loading=\"lazy\" title=\"OFF-GRID. PIP 4048MS. Working in Parallel mode\" width=\"980\" height=\"551\" src=\"https:\/\/www.youtube.com\/embed\/_FJhHsDZBrk?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe><\/p>\n<p><iframe loading=\"lazy\" title=\"MPP Solar Inverter Charger PIP 4048MS. Installing the parallel board\" width=\"980\" height=\"551\" src=\"https:\/\/www.youtube.com\/embed\/aJo6eHCrYxk?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe><\/p>\n<\/li><li data-href=\"tab-4\" class=\"\" ><ul>\n<li><a href=\"http:\/\/www.mppsolar.com\/manual\/Watchpower%20(off-grid)\/WatchPower%20user%20manual.pdf\"><span style=\"color: #0000ff;\">WatchPower User Manual<\/span><\/a><\/li>\n<\/ul>\n<p>**For WatchPower software please contact our Sales team <span style=\"color: #0000ff;\"><a href=\"mailto:sales@mppsolar.com\"><span style=\"color: #0000ff;\">sales@mppsolar.com<\/span><\/a><\/span> directly.<\/p>\n<\/li><\/ul>\n<div id=\"s3gt_translate_tooltip_mini\" class=\"s3gt_translate_tooltip_mini_box\" style=\"background: initial !important; border: initial !important; border-radius: initial !important; border-spacing: initial !important; border-collapse: initial !important; direction: ltr !important; flex-direction: initial !important; font-weight: initial !important; height: initial !important; letter-spacing: initial !important; min-width: initial !important; max-width: initial !important; min-height: initial !important; max-height: initial !important; margin: auto !important; outline: initial !important; padding: initial !important; position: absolute; table-layout: initial !important; text-align: initial !important; text-shadow: initial !important; width: initial !important; word-break: initial !important; word-spacing: initial !important; overflow-wrap: initial !important; box-sizing: initial !important; display: initial !important; color: inherit !important; font-size: 13px !important; font-family: X-LocaleSpecific, sans-serif, Tahoma, Helvetica !important; line-height: 13px !important; vertical-align: top !important; white-space: inherit !important; left: 782px; top: 1982px; opacity: 0.35;\">\n<div id=\"s3gt_translate_tooltip_mini_logo\" class=\"s3gt_translate_tooltip_mini\" title=\"Translate selected text\"><\/div>\n<div id=\"s3gt_translate_tooltip_mini_sound\" class=\"s3gt_translate_tooltip_mini\" title=\"Play\"><\/div>\n<div id=\"s3gt_translate_tooltip_mini_copy\" class=\"s3gt_translate_tooltip_mini\" title=\"Copy text to Clipboard\"><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>PIP-HS\/MS\/MG PF1 SERIES<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-3699","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/3699","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/comments?post=3699"}],"version-history":[{"count":1,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/3699\/revisions"}],"predecessor-version":[{"id":11582,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/3699\/revisions\/11582"}],"wp:attachment":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/media?parent=3699"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}