{"id":3693,"date":"2017-04-30T04:42:48","date_gmt":"2017-04-30T04:42:48","guid":{"rendered":"https:\/\/www.mppsolar.com\/v3\/?page_id=3693"},"modified":"2018-01-04T04:23:36","modified_gmt":"2018-01-04T04:23:36","slug":"pip-hs-series","status":"publish","type":"page","link":"https:\/\/www.mppsolar.com\/v3\/pip-hs-series\/","title":{"rendered":"PIP-HS Series"},"content":{"rendered":"<h3><span style=\"color: #000080;\">PIP-HS SERIES<\/span><\/h3>\n<hr \/>\n<ul class='tabs'><li><a data-href=\"tab-0\" class=\"gdl-title active\" >OVERVIEW<\/a><\/li><li><a data-href=\"tab-1\" class=\"gdl-title \" >FEATURES<\/a><\/li><li><a data-href=\"tab-2\" class=\"gdl-title \" >CATALOGS<\/a><\/li><li><a data-href=\"tab-3\" class=\"gdl-title \" >VIDEO<\/a><\/li><li><a data-href=\"tab-4\" class=\"gdl-title \" >MONITORING<\/a><\/li><\/ul><ul class='tabs-content'><li data-href=\"tab-0\" class=\"active\" ><p class=\"text\">The <span style=\"color: #0000ff;\">PIP-HS series <\/span>is a versatile high frequency Pure Sine Wave inverter-charger designed for both off-grid or with grid (as backup) application. This series features a light weight and compact design, contains a 50A max PWM solar charger, as well a utility charger ranging from 20A to 60A.\u00a0 The 48v models feature a dual source charging capability (AC + Solar) and the maximum system charging current range from max 50A for 12 and 24v models, up to 110A for 48v models.<\/p>\n<p class=\"text\">PIP-HS features a wide input range support from 90~280VAC (Appliance Mode) and 170~280V (UPS Mode). This is especially important and useful for areas with unstable grid power supply. Similar to our other series of solar inverter-charger, PIP-HS also offers <span style=\"color: #0000ff;\">AC or DC (solar) priority modes<\/span>, and the controls can be easily modified from LCD menu that offers comprehensive system information.\u00a0It also comes with a USB port that can be connected to a PC for system monitoring.\u00a0 When selected to operate in DC (solar) priority mode, inverter will increase charging current from Solar source whenever possible, while reducing current from utility sources.<\/p>\n<p class=\"text\">&#8220;<span style=\"color: #0000ff;\">Stackable<\/span>&#8221; or &#8220;<span style=\"color: #0000ff;\">parallel-ready<\/span>&#8221; version is available on select 48v models only and allows users to expand output of an inverter system by integrating the output circuits of all paralleled units.\u00a0 <strong>Maximum parallel number of units is 6<\/strong>, so users can configure a parallel system either as:<\/p>\n<div class=\"shortcode-list shortcode-list-bullet\"><\/p>\n<ul>\n<li><span style=\"color: #333399;\">Single phase output up to 24kw using 6 units, OR<\/span><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-3047\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2015\/01\/parallel2.jpg\" alt=\"\" width=\"600\" height=\"291\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2015\/01\/parallel2.jpg 600w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2015\/01\/parallel2-300x146.jpg 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/li>\n<li><span style=\"color: #333399;\">Three phase output using either 3 units (12kw) or max 6 units (24kw)<\/span><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-3046\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2015\/01\/parallel3.jpg\" alt=\"\" width=\"600\" height=\"305\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2015\/01\/parallel3.jpg 600w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2015\/01\/parallel3-300x153.jpg 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/li>\n<\/ul>\n<p><\/div>\n<p>For more information, please download the catalogs at the tab page above or contact our sales office at <span style=\"color: #0000ff;\"><a href=\"mailto:sales@mppsolar.com\"><span style=\"color: #0000ff;\">sales@mppsolar.com<\/span><\/a><\/span>.<\/p>\n<\/li><li data-href=\"tab-1\" class=\"\" ><div class=\"shortcode-list shortcode-list-check\"><\/p>\n<ul>\n<li><span style=\"color: #ff0000;\">NEW! PIP-1212HS (1.2kw, 12vdc) available now<br \/>\n<\/span><\/li>\n<li>High frequency pure sine wave output, light-weight design<\/li>\n<li>Programmable modes on LCD, e.g. AC priority vs. Solar(DC) priority<\/li>\n<li>Adjustable Bulk\/Float charging voltage<\/li>\n<li>Support lead acid and LiFePo4 batteries<\/li>\n<li><span style=\"color: #000000;\">Support 1-phase or 3-phase PARALLEL output up to 6 units (48v models only, require parallel kit to work)<\/span><\/li>\n<li>Indoor installation only<\/li>\n<li>Built-in solar charger (max 50A)<\/li>\n<li>3-stage battery charger (max 60A on 48v models only)<\/li>\n<li><span style=\"color: #000000;\">total max charging current 50A + 60A = 110A! (on 48v models only)<\/span><\/li>\n<li>2x surge capacity<\/li>\n<li>Wide AC input ranges<\/li>\n<li>LCD + LED indicators<\/li>\n<li><span style=\"color: #000000;\">FREE monitoring software<\/span><\/li>\n<li><span style=\"color: #000000;\">Built-in generator starter dry-contact<\/span><\/li>\n<\/ul>\n<p><\/div>\n<div class=\"message-box-wrapper red\"><div class=\"message-box-title\">Using Generator as AC-Input<\/div><div class=\"message-box-content\"><\/p>\n<ul>\n<li>Generator size should be sized at least 150% larger than the inverter rating to reduce chances of overload.<\/li>\n<li>Inverter-generator is recommended due to its cleaner output than conventional generators.\u00a0 Unsuitable generator output may be rejected by the inverter.<\/li>\n<\/ul>\n<p>\n<\/div><\/div>\n<\/li><li data-href=\"tab-2\" class=\"\" ><ul>\n<li><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/PIP-HS.pdf\">PIP-HS Series Catalog PDF<\/a><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/PIP-HS_MS%20Parallel%20Guide.pdf\">PIP-MS Parallel Guide<\/a><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/PIP-HS_MS%20genset%20requirement.pdf\">Generator Requirement<\/a><\/span><\/li>\n<\/ul>\n<\/li><li data-href=\"tab-3\" class=\"\" ><p><iframe loading=\"lazy\" width=\"980\" height=\"551\" src=\"https:\/\/www.youtube.com\/embed\/A5tX0xkYYrc?feature=oembed\" frameborder=\"0\" gesture=\"media\" allow=\"encrypted-media\" allowfullscreen><\/iframe><\/p>\n<p><iframe loading=\"lazy\" width=\"980\" height=\"551\" src=\"https:\/\/www.youtube.com\/embed\/BQBqLfNU7SY?feature=oembed\" frameborder=\"0\" gesture=\"media\" allow=\"encrypted-media\" allowfullscreen><\/iframe><\/p>\n<p><iframe loading=\"lazy\" width=\"980\" height=\"551\" src=\"https:\/\/www.youtube.com\/embed\/_FJhHsDZBrk?feature=oembed\" frameborder=\"0\" gesture=\"media\" allow=\"encrypted-media\" allowfullscreen><\/iframe><\/p>\n<p><iframe loading=\"lazy\" width=\"980\" height=\"551\" src=\"https:\/\/www.youtube.com\/embed\/aJo6eHCrYxk?feature=oembed\" frameborder=\"0\" gesture=\"media\" allow=\"encrypted-media\" allowfullscreen><\/iframe><\/p>\n<hr \/>\n<div class=\"shortcode1-2\"><div style=\"max-width:300px;\" ><iframe loading=\"lazy\" src=\"http:\/\/www.youtube.com\/embed\/_FJhHsDZBrk?wmode=transparent\" width=\"300\" height=\"250\" ><\/iframe><\/div>\n<\/div>\n<div class=\"shortcode1-2\"><div style=\"max-width:300px;\" ><iframe loading=\"lazy\" src=\"http:\/\/www.youtube.com\/embed\/aJo6eHCrYxk?wmode=transparent\" width=\"300\" height=\"250\" ><\/iframe><\/div>\n<\/div>\n<\/li><li data-href=\"tab-4\" class=\"\" ><ul>\n<li><a href=\"http:\/\/www.mppsolar.com\/manual\/Watchpower%20(HS_MS)\/WatchPower_user_manual.pdf\"><span style=\"color: #0000ff;\">WatchPower User Manual<\/span><\/a><\/li>\n<\/ul>\n<p>**For WatchPower software please contact our Sales team <span style=\"color: #0000ff;\"><a href=\"mailto:sales@mppsolar.com\"><span style=\"color: #0000ff;\">sales@mppsolar.com<\/span><\/a><\/span> directly.<\/p>\n<\/li><\/ul>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>PIP-HS SERIES &nbsp;<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-3693","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/3693","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/comments?post=3693"}],"version-history":[{"count":0,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/3693\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/media?parent=3693"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}