{"id":3583,"date":"2016-09-27T11:25:50","date_gmt":"2016-09-27T11:25:50","guid":{"rendered":"https:\/\/www.mppsolar.com\/v3\/?page_id=3583"},"modified":"2023-08-19T01:01:03","modified_gmt":"2023-08-19T01:01:03","slug":"hybrid-v-series","status":"publish","type":"page","link":"https:\/\/www.mppsolar.com\/v3\/hybrid-v-series\/","title":{"rendered":"Hybrid V \/ V2 Series"},"content":{"rendered":"<h3><\/h3>\n<ul class='tabs'><li><a data-href=\"tab-0\" class=\"gdl-title active\" >OVERVIEW<\/a><\/li><li><a data-href=\"tab-1\" class=\"gdl-title \" >FEATURES<\/a><\/li><li><a data-href=\"tab-2\" class=\"gdl-title \" >CATALOG<\/a><\/li><li><a data-href=\"tab-3\" class=\"gdl-title \" >MONITORING<\/a><\/li><\/ul><ul class='tabs-content'><li data-href=\"tab-0\" class=\"active\" ><p class=\"text\">The <span style=\"color: #0000ff;\"><span style=\"color: #000000;\"><strong>Hybrid V\/<span style=\"color: #0000ff;\">V2<\/span> Series<\/strong>, like all hybrid family inverters<\/span><\/span>, <mark><span style=\"text-decoration: underline;\">offer additional capability to export power to grid when there&#8217;s surplus energy from solar panels, after satisfying load + battery<\/span><\/mark>.\u00a0 One unique advantage of the HV\/V2 series is the freedom of true hybrid systems, without constraints of specific national standards so users can typically use this in a wider range of environment.<\/p>\n<p>On the brand new <span style=\"color: #0000ff;\"><strong>V2 Series (3K, 5K)<\/strong><\/span>, 3 main features have been added to further enhance the capability of V2 models.<\/p>\n<div class=\"shortcode-list shortcode-list-check\"><\/p>\n<ul>\n<li><span style=\"color: #ff0000;\"><strong>Batteryless operation<\/strong><\/span><\/li>\n<li><span style=\"color: #ff0000;\"><strong>Parallel operation up to 9 units max<\/strong><\/span><\/li>\n<li><strong><span style=\"color: #ff0000;\">Max PV input up to 450V<\/span><br \/>\n<\/strong><\/li>\n<\/ul>\n<p><\/div>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-4313\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2019\/07\/\u64f7\u53d6.png\" alt=\"\" width=\"1417\" height=\"434\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2019\/07\/\u64f7\u53d6.png 1417w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2019\/07\/\u64f7\u53d6-600x184.png 600w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2019\/07\/\u64f7\u53d6-300x92.png 300w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2019\/07\/\u64f7\u53d6-768x235.png 768w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2019\/07\/\u64f7\u53d6-1024x314.png 1024w\" sizes=\"auto, (max-width: 1417px) 100vw, 1417px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-4315\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2019\/07\/9parallelsp.jpg\" alt=\"\" width=\"828\" height=\"297\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2019\/07\/9parallelsp.jpg 828w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2019\/07\/9parallelsp-600x215.jpg 600w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2019\/07\/9parallelsp-300x108.jpg 300w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2019\/07\/9parallelsp-768x275.jpg 768w\" sizes=\"auto, (max-width: 828px) 100vw, 828px\" \/><\/p>\n<div class=\"message-box-wrapper yellow\"><div class=\"message-box-title\">Important note about Batteryless Operation<\/div><div class=\"message-box-content\"><p>When configuring system in parallel using multiple units, please be sure that a battery <strong>MUST <\/strong>be used or otherwise it may cause system to work incorrectly, or possibly lead to damage.\u00a0 Due to the inconsistent nature of PV power, batteryless mode can only work normally under single-unit setup.<\/p>\n<\/div><\/div>\n<div class=\"message-box-wrapper red\"><div class=\"message-box-title\">PV panel selection for HV2 models<\/div><div class=\"message-box-content\"><p> Because the HV2 is designed based on high PV input which should require uses to wire panels in series as much as possible, without exceeding the max PV input limit.\u00a0 When selecting panels, be sure to use &#8220;non-grounding&#8221; panels as otherwise this could cause a leakage current problem on the HV2 inverters which are non-isolated design. <\/p>\n<\/div><\/div>\n<div class=\"message-box-wrapper green\"><div class=\"message-box-title\">Generator Support<\/div><div class=\"message-box-content\"><p> Genset starter dry contact is a standard feature in this model, and in the absence of grid, users may opt to connect a generator for backup.\u00a0 Only quality inverter-type generators are recommended for use.<\/p>\n<\/div><\/div>\n<p>&nbsp;<\/p>\n<\/li><li data-href=\"tab-1\" class=\"\" ><p>Main features include:<\/p>\n<div class=\"shortcode-list shortcode-list-check\"><\/p>\n<ul>\n<li><span style=\"color: #0000ff;\">NEW! Max PV input up to 450V (V2 only)<\/span><\/li>\n<li><span style=\"color: #0000ff;\">NEW! Parallel support up to 9 units<br \/>\n<\/span><\/li>\n<li><span style=\"color: #0000ff;\">NEW! Batteryless operation (V2 only)<\/span><\/li>\n<li><span style=\"color: #000000;\">Hybrid mode allows export of surplus PV energy to grid<\/span><\/li>\n<li><span style=\"color: #000000;\">Dual MPPT trackers (5KW only)<\/span><\/li>\n<li><span style=\"color: #000000;\">Timer charging control<\/span><\/li>\n<li><span style=\"color: #000000;\">Pure sine wave output 3-5KW<\/span><\/li>\n<li><span style=\"color: #000000;\">Max PV input power up to 6KW<br \/>\n<\/span><\/li>\n<li><span style=\"color: #000000;\">Max PV input voltage up to 145V<\/span><\/li>\n<li><span style=\"color: #000000;\">Max solar charging up to 120A (HV 5K only)<br \/>\n<\/span><\/li>\n<li><span style=\"color: #000000;\">Supports generator use with genset starter dry contact<br \/>\n<\/span><\/li>\n<li><span style=\"color: #000000;\">Programmable parameters<\/span><\/li>\n<li><span style=\"color: #000000;\">Lightweight, easy to install<\/span><\/li>\n<li><span style=\"color: #000000;\">Free monitoring software<\/span><\/li>\n<li><span style=\"color: #000000;\">USB, RS232 communication interface<\/span><\/li>\n<\/ul>\n<p><\/div>\n<\/li><li data-href=\"tab-2\" class=\"\" ><ul>\n<li><a href=\"http:\/\/www.mppsolar.com\/v3\/catalogs\/HYBRID%20V_V2.pdf\"><span style=\"color: #0000ff;\">Hybrid V\/V2 Series<\/span><\/a><\/li>\n<\/ul>\n<\/li><li data-href=\"tab-3\" class=\"\" ><ul>\n<li><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"http:\/\/www.mppsolar.com\/manual\/SolarPower%20%28hybrid%29\/manual\/solarpowermanual.pdf\">SolarPower Manual<\/a><\/span><\/li>\n<\/ul>\n<p>**For SolarPower software please contact our Sales team <span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"mailto:sales@mppsolar.com\">sales@mppsolar.com<\/a><\/span> directly.<\/p>\n<\/li><\/ul>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-3583","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/3583","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/comments?post=3583"}],"version-history":[{"count":2,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/3583\/revisions"}],"predecessor-version":[{"id":12553,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/3583\/revisions\/12553"}],"wp:attachment":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/media?parent=3583"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}