{"id":3555,"date":"2016-08-06T03:22:50","date_gmt":"2016-08-06T03:22:50","guid":{"rendered":"https:\/\/www.mppsolar.com\/v3\/?page_id=3555"},"modified":"2025-10-31T07:46:47","modified_gmt":"2025-10-31T07:46:47","slug":"110v-120v-low-voltage-series-2","status":"publish","type":"page","link":"https:\/\/www.mppsolar.com\/v3\/110v-120v-low-voltage-series-2\/","title":{"rendered":"PIP-LV 110-120V Low Voltage Series"},"content":{"rendered":"<h3><\/h3>\n<ul class='tabs'><li><a data-href=\"tab-0\" class=\"gdl-title active\" >OVERVIEW<\/a><\/li><li><a data-href=\"tab-1\" class=\"gdl-title \" >FEATURES<\/a><\/li><li><a data-href=\"tab-2\" class=\"gdl-title \" >CATALOGS<\/a><\/li><li><a data-href=\"tab-3\" class=\"gdl-title \" >MONITORING<\/a><\/li><\/ul><ul class='tabs-content'><li data-href=\"tab-0\" class=\"active\" ><p class=\"text\">This special new <span style=\"color: #0000ff;\">110v\/120v Low Voltage<\/span> series is designed with special focus to countries such as US, Canada, Puerto Rico, and other regions which use primarily 110V\/120V load without the need for an external step-down transformer.\u00a0 <strong>Please be careful this unit does NOT work with 220-240v load.<\/strong><\/p>\n<p class=\"text\">Available from 800w to 2400w<span style=\"color: #0000ff;\">, <span style=\"color: #000000;\">a<\/span><\/span>ll models in this series come with either MPPT or PWM solar charger and also offer free monitoring on PC which is bundled with purchase.\u00a0 Stackable feature up to 6 units maximum is available only on 2424LV-HS and 2424LV-MSD, increasing max output capacity up to 2.4KW x 6 = 14.4KW.\u00a0 Below is a simple diagram illustrating parallel setup, and parallel kit (sold separately) is also required on each inverter unit.<\/p>\n<p class=\"text\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-3565\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2016\/08\/lvparallel-300x146.jpg\" alt=\"\u7121\u6a19\u984c-1\" width=\"495\" height=\"241\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2016\/08\/lvparallel-300x146.jpg 300w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2016\/08\/lvparallel.jpg 600w\" sizes=\"auto, (max-width: 495px) 100vw, 495px\" \/><\/p>\n<p>For more information, please download the catalogs at the tab page above or contact our sales office at <span style=\"color: #0000ff;\"><a href=\"mailto:sales@mppsolar.com\"><span style=\"color: #0000ff;\">sales@mppsolar.com<\/span><\/a><\/span>.<\/p>\n<\/li><li data-href=\"tab-1\" class=\"\" ><ol>\n<li><span style=\"color: #ff0000;\">NEW!\u00a0 1012LV-MS is now available as an updated PF1.0 version of the previous 812LV-MS. Maximum output is now 1KW.<br \/>\n<\/span><\/li>\n<li><span style=\"color: #0000ff;\">110V \/ 120V adjustable output design for low voltage standard markets like USA, Canada<\/span><\/li>\n<li><span style=\"color: #0000ff;\">Stackable \u2014 supports parallel operation up to 6 units (only on 2424LV-HS, 2424LV-MSD)<\/span><\/li>\n<li><span style=\"color: #0000ff;\">Pure sine wave inverter with built\u2013in max 50A PWM or max up to 80A MPPT solar controller <\/span><span style=\"color: #0000ff;\"><br \/>\n<\/span><\/li>\n<li><span style=\"color: #0000ff;\">50Hz &amp; 60Hz support<\/span><\/li>\n<li>Selectable AC input volt range based on load type<\/li>\n<li>Programmable parameters<\/li>\n<li>Max up to 60A utility charging<\/li>\n<li>Adjustable bulk &amp; float charging voltage<\/li>\n<li>Support either grid or generator input<\/li>\n<li>Genset starter dry contact<\/li>\n<li>Overload and short circuit protection<\/li>\n<li>Lightweight, easy to install<\/li>\n<li>FREE monitoring software<\/li>\n<li>LCD Display + LED indicators<\/li>\n<li>RS232\/USB communication interface<\/li>\n<\/ol>\n<p>&nbsp;<\/p>\n<div class=\"message-box-wrapper red\"><div class=\"message-box-title\">Using Generator as AC-Input<\/div><div class=\"message-box-content\"><\/p>\n<ol>\n<li>Generator power is recommended to be 50% larger than the inverter rating to reduce chances of overload.<\/li>\n<li>Inverter-generator is recommended due to its cleaner output than conventional generators.\u00a0 Unsuitable generator output may be rejected by the inverter.<\/li>\n<\/ol>\n<p>\n<\/div><\/div>\n<\/li><li data-href=\"tab-2\" class=\"\" ><ol>\n<li><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/PIP-LV.pdf\">Low Voltage Series Catalog PDF<\/a><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/PIP-HS_MS%20Parallel%20Guide.pdf\">Parallel Guide<\/a><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/generator%20requirement.pdf\">Generator Requirement<\/a><\/span><\/li>\n<\/ol>\n<\/li><li data-href=\"tab-3\" class=\"\" ><ol>\n<li><a href=\"http:\/\/www.mppsolar.com\/manual\/Watchpower%20(off-grid)\/WatchPower%20v1.13SP3%20(latest)\/WatchPower%20user%20manual.pdf\"><span style=\"color: #0000ff;\">WatchPower User Manual<\/span><\/a><\/li>\n<\/ol>\n<p>**For WatchPower software please contact our Sales team <span style=\"color: #0000ff;\"><a href=\"mailto:sales@mppsolar.com\"><span style=\"color: #0000ff;\">sales@mppsolar.com<\/span><\/a><\/span> directly.<\/p>\n<\/li><\/ul>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-3555","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/3555","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/comments?post=3555"}],"version-history":[{"count":4,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/3555\/revisions"}],"predecessor-version":[{"id":13359,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/3555\/revisions\/13359"}],"wp:attachment":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/media?parent=3555"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}