{"id":3529,"date":"2016-06-13T07:29:25","date_gmt":"2016-06-13T07:29:25","guid":{"rendered":"https:\/\/www.mppsolar.com\/v3\/?page_id=3529"},"modified":"2024-10-23T03:18:23","modified_gmt":"2024-10-23T03:18:23","slug":"sp-series-3-phase","status":"publish","type":"page","link":"https:\/\/www.mppsolar.com\/v3\/sp-series-3-phase\/","title":{"rendered":"SP Series (Single Phase, 3-Phase)"},"content":{"rendered":"<h3><span style=\"color: #000080;\">SP SERIES (Single Phase, 3-Phase)<br \/>\n<\/span><\/h3>\n<hr \/>\n<ul class='tabs'><li><a data-href=\"tab-0\" class=\"gdl-title active\" >OVERVIEW<\/a><\/li><li><a data-href=\"tab-1\" class=\"gdl-title \" >FEATURES<\/a><\/li><li><a data-href=\"tab-2\" class=\"gdl-title \" >DOCUMENTATION<\/a><\/li><li><a data-href=\"tab-3\" class=\"gdl-title \" >CALCULATOR<\/a><\/li><\/ul><ul class='tabs-content'><li data-href=\"tab-0\" class=\"active\" ><p class=\"text\">The SP series solar pump inverters are available in two main types:<\/p>\n<div class=\"shortcode-list shortcode-list-check\"><\/p>\n<ul>\n<li><span style=\"color: #0000ff;\"><strong>SP-2.2K LS (2.2KW, supports both single phase or 3-phase)<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>SP-2.2K, 7.5K, 11K,<span style=\"color: #ff0000;\"> 15KW<\/span> (3-phase only)<br \/>\n<\/strong><\/span><\/li>\n<\/ul>\n<p><\/div>\n<p class=\"text\">and they offer battery-less operation by converting solar energy directly into AC power that drives water pumps.\u00a0\u00a0 This helps reduce overall system cost by offering excellent autonomy and low maintenance expense which is crucial in farming.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3532 aligncenter\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2016\/06\/solarpump_3.jpg\" alt=\"\" width=\"600\" height=\"250\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2016\/06\/solarpump_3.jpg 600w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2016\/06\/solarpump_3-300x125.jpg 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/p>\n<p class=\"text\">The high efficiency<span style=\"color: #0000ff;\"> SP series<\/span> allows PV input of up to 800V (Voc) and includes built-in MPPT technology to maximize the return from your solar array.\u00a0 Output voltage for single phase model 2.2k LS is based on 220-240V (Single Phase or 3-Phase motors), and for 3-phase models are 380, 400, 415 or 440VAC, (3-Phase motors only).\u00a0 In the event when solar energy is not available, users still have the option to manually use AC input sources such as grid or a 3-phase generator to power the pump (bonus feature).<\/p>\n<p>For more information, please download the catalogs at the tab page above or contact our sales office at <span style=\"color: #0000ff;\"><a href=\"mailto:sales@mppsolar.com\"><span style=\"color: #0000ff;\">sales@mppsolar.com<\/span><\/a><\/span>.<\/p>\n<div class=\"message-box-wrapper yellow\"><div class=\"message-box-title\"><strong>IMPORTANT: MOTOR TYPE<\/strong><\/div><div class=\"message-box-content\"><\/p>\n<ul>\n<li><b>Due to different software controls, synchronous type motors are NOT supported. Only asynchronous type pumps can be used.<\/b><\/li>\n<\/ul>\n<p>\n<\/div><\/div>\n<div class=\"message-box-wrapper red\"><div class=\"message-box-title\"><strong>IMPORTANT: ON 3-PHASE MODELS ONLY<\/strong><\/div><div class=\"message-box-content\"><\/p>\n<ul>\n<li><strong>This inverter uses &#8220;either&#8221; solar or AC input source to power load.\u00a0 Please remember to NEVER connect both power sources (solar and AC input) at the same time as this will result in instantaneous damage of the inverter and will void product warranty!<\/strong><\/li>\n<\/ul>\n<p>\n<\/div><\/div>\n<\/li><li data-href=\"tab-1\" class=\"\" ><div class=\"shortcode-list shortcode-list-check\"><\/p>\n<ul>\n<li><strong><span style=\"color: #ff0000;\">Battery-less design solar pump inverter (run from Solar or AC directly)<\/span><\/strong><\/li>\n<li><strong><span style=\"color: #ff0000;\">Built in MPPT algorithm<\/span><\/strong><\/li>\n<li><span style=\"color: #ff0000;\"><strong>High PV input volt up to 450V (Voc) for LS model \/ 800V (Voc) for 3-phase models<\/strong><br \/>\n<\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong><span style=\"color: #800080;\">2.2K LS<\/span> (2.2KW, 220-240V output, single phase or 3-phase motors),<br \/>\n<span style=\"color: #800080;\">2.2K\/7.5K\/11K\/15K<\/span> (2.2KW, 7.5KW, 11KW, 15KW, 380-440V output, 3-phase motors only)<\/strong><br \/>\n<\/span><\/li>\n<li>Compatible with IEC standard 3-phase asynchronous motors only<\/li>\n<li>Peak 97% efficiency!<\/li>\n<li>50Hz or 60Hz supported (programmable)<\/li>\n<li>Reserved AC Input \u2014 compatible with utility or generator<\/li>\n<li>Auto-restart feature after PV reconnect or AC return<\/li>\n<li>Automatic derating at high temperature<\/li>\n<li>Soft start feature available<\/li>\n<li>Full feature system protection<\/li>\n<li>RS232 \/ RS485 monitoring feature (require optional RS485\/RS232 converter)<\/li>\n<li>Large LCD \/ LED display<\/li>\n<li>(optional) Monitoring of water tank level through input dry contact signal<\/li>\n<\/ul>\n<p><\/div>\n<\/li><li data-href=\"tab-2\" class=\"\" ><ul>\n<li><span style=\"color: #0000ff;\"><strong><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/SP%20PUMP%20INV.pdf\">Solar Pump Inverter Catalog PDF<\/a><br \/>\n<\/strong><\/span><\/li>\n<li><a href=\"http:\/\/www.mppsolar.com\/manual\/Solar%20Pump%20Inverter\/Solar%20pump%20inverter%202.2kw%20LS%20manual.pdf\"><span style=\"color: #0000ff;\"><strong>Solar Pump Inverer User Manual PDF (LS 2.2K)<\/strong><\/span><\/a><\/li>\n<li><a href=\"http:\/\/www.mppsolar.com\/manual\/Solar%20Pump%20Inverter\/Solar%20pump%20inverter%203phase%20(2.2,%207.5,%2011kw)%20manual.pdf\"><span style=\"color: #0000ff;\"><strong>Solar Pump Inverer User Manual PDF (3P 2K &#8211; 11K)<\/strong><\/span><\/a><\/li>\n<li><a href=\"http:\/\/www.mppsolar.com\/manual\/Solar%20Pump%20Inverter\/Solar%20pump%20inverter%203phase%20(15kw)%20manual.pdf\"><span style=\"color: #0000ff;\"><strong>Solar Pump Inverer User Manual PDF (3P 15K)<\/strong><\/span><\/a><\/li>\n<li><a href=\"http:\/\/www.mppsolar.com\/manual\/Solar%20Pump%20Inverter\/Remote%20Monitoring%20quick%20guide-20170322.pdf\"><span style=\"color: #0000ff;\"><strong>Remote Monitoring Guide<\/strong><\/span><\/a><\/li>\n<\/ul>\n<\/li><li data-href=\"tab-3\" class=\"\" ><ul>\n<li><a href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/PV_array_calculator.xlsx\"><span style=\"color: #0000ff;\">PV array calculator (Excel)<\/span><\/a><\/li>\n<\/ul>\n<\/li><\/ul>\n","protected":false},"excerpt":{"rendered":"<p>SP SERIES (Single Phase, 3-Phase)<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-3529","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/3529","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/comments?post=3529"}],"version-history":[{"count":4,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/3529\/revisions"}],"predecessor-version":[{"id":13207,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/3529\/revisions\/13207"}],"wp:attachment":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/media?parent=3529"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}