{"id":3329,"date":"2016-02-22T07:56:14","date_gmt":"2016-02-22T07:56:14","guid":{"rendered":"https:\/\/www.mppsolar.com\/v3\/?page_id=3329"},"modified":"2016-05-18T07:23:00","modified_gmt":"2016-05-18T07:23:00","slug":"pcm50cv","status":"publish","type":"page","link":"https:\/\/www.mppsolar.com\/v3\/pcm50cv\/","title":{"rendered":"PCM50CV"},"content":{"rendered":"<h3><span style=\"color: #808000;\">PCM50CV SERIES<\/span><\/h3>\n<ul class='tabs'><li><a data-href=\"tab-0\" class=\"gdl-title active\" >OVERVIEW<\/a><\/li><li><a data-href=\"tab-1\" class=\"gdl-title \" >FEATURES<\/a><\/li><li><a data-href=\"tab-2\" class=\"gdl-title \" >CATALOG<\/a><\/li><li><a data-href=\"tab-3\" class=\"gdl-title \" >VIDEO<\/a><\/li><\/ul><ul class='tabs-content'><li data-href=\"tab-0\" class=\"active\" ><p class=\"text\">The<span style=\"color: #0000ff;\"> PCM50CV <\/span>MPPT controller is a special customized version of our <a href=\"https:\/\/www.mppsolar.com\/v3\/pcm50488048cx-series\/\">PCM5048\/8048\/CX series<\/a> chargers.\u00a0 The main purpose of this special charger is to target industrial applications of energy systems that use 48V, 72V, 96V or 120VDC high voltage battery systems.\u00a0 The max PV input voltage on this model is raised to 480VDC (open circuit voltage) and the MPPT range is now as follows:<\/p>\n<p class=\"text\"><div class=\"shortcode-list shortcode-list-arrow\"><\/p>\n<ul>\n<li>48V system: 64 ~ 384VDC<\/li>\n<li>72V system: 96 ~ 384VDC<\/li>\n<li>96V system: 128 ~ 384VDC<\/li>\n<li>120V system: 160 ~ 384VDC<\/li>\n<\/ul>\n<p><\/div><\/p>\n<p class=\"text\">The maximum charging current of the 50CV is capped at 50A, and based on equalization charge of 160V on 120VDC systems, a single unit of this charger can support up to 8KW of PV array max!<\/p>\n<p class=\"text\">With 50CV, customers no longer need to rely on expensive grid or generator charging; also, capable of charging 120VDC batteries, users can avoid the adverse long-term effect of &#8220;split charging&#8221; of a battery system, which will lead to internal imbalance over time.<\/p>\n<p class=\"text\">\n<\/li><li data-href=\"tab-1\" class=\"\" ><\/p>\n<p>Main features:<\/p>\n<div class=\"shortcode-list shortcode-list-check\"><\/p>\n<ul>\n<li><span style=\"color: #ff0000;\">Ultra high voltage input 480VDC!<\/span><\/li>\n<li><span style=\"color: #ff0000;\">Supports high voltage battery systems 48V\/72V\/96V\/120V only<\/span><\/li>\n<li><span style=\"color: #ff0000;\">Large array PV array support up to 8KW*<\/span><\/li>\n<li><span style=\"color: #ff0000;\">Maximum charging current up to 50A<\/span><\/li>\n<li>Programmable charging<\/li>\n<li>Support Wet, AGM, and Gel batteries<\/li>\n<li>Allows peer data parallel connections up to 16 units<\/li>\n<li>4 LEDs and large LCD screen to display device modes and important system information<\/li>\n<li>Integrated Battery Monitor to display energy information in battery**<\/li>\n<li>Data logging storage up to 90 days<\/li>\n<li>Built-in temperature compensation capability<\/li>\n<li>Over-temp, PV input overload, reverse current, battery overcharge\/undercharge protection<\/li>\n<li>2 sets of built-in Auxiliary Relays for device control<\/li>\n<li>Manual or automatic battery equalization<\/li>\n<li>CE certified<\/li>\n<\/ul>\n<p><\/div>\n<p><span style=\"color: #808080;\"><em>*based on max equalization charge on a 120v battery bank at 160V.<\/em><\/span><br \/>\n<span style=\"color: #808080;\"><em>**This feature requires optional accessory 500A\/50mv shunt to activate. Please contact us for more detail.<\/em><\/span><\/p>\n<\/li><li data-href=\"tab-2\" class=\"\" ><ul>\n<li><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/PCM50CV.pdf\">PCM50CV Catalog PDF<\/a><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/PCM_CX%20parallel%20concept.pdf\">Parallel Diagram<\/a><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/PCM_CX%20wiring%20diagram.pdf\">Wiring Diagram<\/a><\/span><\/li>\n<\/ul>\n<\/li><li data-href=\"tab-3\" class=\"\" ><div style=\"max-width:450px;\" ><iframe loading=\"lazy\" src=\"http:\/\/www.youtube.com\/embed\/b1IKqaAjkqM?wmode=transparent\" width=\"450\" height=\"370\" ><\/iframe><\/div>\n<\/li><\/ul>\n","protected":false},"excerpt":{"rendered":"<p>PCM50CV SERIES<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-3329","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/3329","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/comments?post=3329"}],"version-history":[{"count":0,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/3329\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/media?parent=3329"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}