{"id":2139,"date":"2013-04-25T06:48:01","date_gmt":"2013-04-25T06:48:01","guid":{"rendered":"https:\/\/www.mppsolar.com\/v3\/?page_id=2139"},"modified":"2018-01-04T04:23:29","modified_gmt":"2018-01-04T04:23:29","slug":"pip-ms-series","status":"publish","type":"page","link":"https:\/\/www.mppsolar.com\/v3\/pip-ms-series\/","title":{"rendered":"PIP-MS\/MSX Series"},"content":{"rendered":"<h3><span style=\"color: #000080;\">PIP-MS\/MSX SERIES<\/span><\/h3>\n<hr \/>\n<ul class='tabs'><li><a data-href=\"tab-0\" class=\"gdl-title active\" >OVERVIEW<\/a><\/li><li><a data-href=\"tab-1\" class=\"gdl-title \" >FEATURES<\/a><\/li><li><a data-href=\"tab-2\" class=\"gdl-title \" >CATALOGS<\/a><\/li><li><a data-href=\"tab-3\" class=\"gdl-title \" >VIDEO<\/a><\/li><li><a data-href=\"tab-4\" class=\"gdl-title \" >MONITORING<\/a><\/li><\/ul><ul class='tabs-content'><li data-href=\"tab-0\" class=\"active\" ><p class=\"text\">The <span style=\"color: #0000ff;\">PIP-MS\/MSX<\/span> series is very similar to the <span style=\"color: #800080;\"><a href=\"https:\/\/www.mppsolar.com\/v3\/pip-hs-series\/\">PIP-HS<\/a><\/span> series inverter-charger, except that it offers a <span style=\"color: #0000ff;\">built-in MPPT solar charger (up to 80A)<\/span> and is now available in 12v, 24v and 48v models from 800W to 4KW.\u00a0 The built-in MPPT solar charger can support PV array up to 4kw max (80amp). The MS\/MSX 48v series also features a dual source charging capability (AC + Solar) and the max charging current from both sources are up to 140A.<\/p>\n<p class=\"text\">PIP-MS\/MSX features a wide input range support from 90~280VAC (Appliance Mode) and 170~280V (UPS Mode). This is especially important and useful for areas with unstable grid power supply. Similar to our other series of solar inverter-charger, PIP-MS\/MSX also offers <span style=\"color: #0000ff;\">AC or DC (solar) priority modes<\/span>, and the controls can be easily modified from LCD menu that offers comprehensive system information.\u00a0It also comes with a USB port that can be connected to a PC for system monitoring.\u00a0 When selected to operate in DC (solar) priority mode, inverter will increase charging current from Solar source whenever possible, while reducing current from utility sources.<\/p>\n<p class=\"text\"><span style=\"color: #000000;\"><span style=\"color: #0000ff;\">PIP-MS<\/span> now <\/span>features a &#8220;<span style=\"color: #0000ff;\">stackable<\/span>&#8221; or &#8220;<span style=\"color: #0000ff;\">parallel<\/span>&#8221; version (applicable to identical 48v same model name only ) which allows users to expand output of an inverter system by integrating the output circuits of each individual unit.\u00a0 <strong>Maximum parallel number of units is now <span style=\"color: #0000ff;\">upgraded to 9<\/span><\/strong>, so users can configure a parallel system either as:<\/p>\n<div class=\"shortcode-list shortcode-list-bullet\"><\/p>\n<ul>\n<li><span style=\"color: #333399;\">Single phase output up to 24kw using 6 units (maximum 9 units), OR<\/span><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-3047\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2015\/01\/parallel2.jpg\" alt=\"\" width=\"600\" height=\"291\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2015\/01\/parallel2.jpg 600w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2015\/01\/parallel2-300x146.jpg 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/li>\n<li><span style=\"color: #333399;\">Three phase output using either 3 units (12kw) or max 6 units (24kw)<\/span><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-3046\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2015\/01\/parallel3.jpg\" alt=\"\" width=\"600\" height=\"305\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2015\/01\/parallel3.jpg 600w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2015\/01\/parallel3-300x153.jpg 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/li>\n<\/ul>\n<p><\/div>\n<p><span style=\"color: #0000ff;\">PIP-MSX<\/span> is a special model which features the upgrade of internal MPPT charger from 25A to 60A.\u00a0 This currently applies only to 1.6kw and 2.4kw model.<\/p>\n<p>For more information, please download the catalogs at the tab page above or contact our sales office at <span style=\"color: #0000ff;\"><a href=\"mailto:sales@mppsolar.com\"><span style=\"color: #0000ff;\">sales@mppsolar.com<\/span><\/a><\/span>.<\/p>\n<\/li><li data-href=\"tab-1\" class=\"\" ><div class=\"shortcode-list shortcode-list-check\"><\/p>\n<ul>\n<li><span style=\"color: #000000;\"><span style=\"color: #0000ff;\"><span style=\"color: #ff0000;\">NEW!<\/span><\/span> <span style=\"color: #ff0000;\">Built-in MPPT solar charger now up to 80A! (3248MS, 4048MS only)<br \/>\n<\/span><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><span style=\"color: #ff0000;\">NEW! Available for order now in 12V model (1212MS) with 60A max utility charging + 40A MPPT solar<br \/>\n<\/span><\/span><\/li>\n<li><span style=\"color: #ff0000;\">NEW! Support 1-phase or 3-phase PARALLEL output up to 9 units (apply to same 48v model names only, require parallel kit to work)<\/span><\/li>\n<li><span style=\"color: #0000ff;\">Available for special order in 110\/120Vac output (1624MSX only)<br \/>\n<\/span><\/li>\n<li>High frequency pure sine wave output, light-weight design<\/li>\n<li>Programmable modes on LCD, e.g. AC priority vs. Solar(DC) priority<\/li>\n<li>Adjustable Bulk\/Float charging voltage<\/li>\n<li>Support lead acid and LiFePo4 batteries<\/li>\n<li>Indoor installation only<\/li>\n<li>3-stage battery charger (max 60A on 48v models only)<span style=\"color: #0000ff;\"><br \/>\n<\/span><\/li>\n<li>Total max charging current = 60A + 80A = 140A!<\/li>\n<li>2x surge capacity<\/li>\n<li>Wide AC input ranges<\/li>\n<li>LCD + LED indicators<\/li>\n<li><span style=\"color: #000000;\">FREE monitoring software<\/span><\/li>\n<li><span style=\"color: #000000;\">Built-in generator starter dry-contact<\/span><\/li>\n<\/ul>\n<p><\/div>\n<div class=\"message-box-wrapper red\"><div class=\"message-box-title\">Using Generator as AC-Input<\/div><div class=\"message-box-content\"><\/p>\n<ul>\n<li>Generator size should be sized at least 150% larger than the inverter rating to reduce chances of overload.<\/li>\n<li>Inverter-generator is recommended due to its cleaner output than conventional generators.\u00a0 Unsuitable generator output may be rejected by the inverter.<\/li>\n<\/ul>\n<p>\n<\/div><\/div>\n<\/li><li data-href=\"tab-2\" class=\"\" ><ul>\n<li><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/PIP-MS.pdf\">PIP-MS\/MSX Series Catalog PDF<\/a><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/PIP-HS_MS%20Parallel%20Guide.pdf\">PIP-MS Parallel Guide<\/a><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/PIP-HS_MS%20genset%20requirement.pdf\">Generator Requirement<\/a><\/span><\/li>\n<\/ul>\n<\/li><li data-href=\"tab-3\" class=\"\" ><p><iframe loading=\"lazy\" width=\"980\" height=\"551\" src=\"https:\/\/www.youtube.com\/embed\/A5tX0xkYYrc?feature=oembed\" frameborder=\"0\" gesture=\"media\" allow=\"encrypted-media\" allowfullscreen><\/iframe><\/p>\n<p><iframe loading=\"lazy\" width=\"980\" height=\"551\" src=\"https:\/\/www.youtube.com\/embed\/BQBqLfNU7SY?feature=oembed\" frameborder=\"0\" gesture=\"media\" allow=\"encrypted-media\" allowfullscreen><\/iframe><\/p>\n<p><iframe loading=\"lazy\" width=\"980\" height=\"551\" src=\"https:\/\/www.youtube.com\/embed\/_FJhHsDZBrk?feature=oembed\" frameborder=\"0\" gesture=\"media\" allow=\"encrypted-media\" allowfullscreen><\/iframe><\/p>\n<p><iframe loading=\"lazy\" width=\"980\" height=\"551\" src=\"https:\/\/www.youtube.com\/embed\/aJo6eHCrYxk?feature=oembed\" frameborder=\"0\" gesture=\"media\" allow=\"encrypted-media\" allowfullscreen><\/iframe><\/p>\n<hr \/>\n<div class=\"shortcode1-2\"><div style=\"max-width:300px;\" ><iframe loading=\"lazy\" src=\"http:\/\/www.youtube.com\/embed\/_FJhHsDZBrk?wmode=transparent\" width=\"300\" height=\"250\" ><\/iframe><\/div>\n<\/div>\n<div class=\"shortcode1-2\"><div style=\"max-width:300px;\" ><iframe loading=\"lazy\" src=\"http:\/\/www.youtube.com\/embed\/aJo6eHCrYxk?wmode=transparent\" width=\"300\" height=\"250\" ><\/iframe><\/div>\n<\/div>\n<\/li><li data-href=\"tab-4\" class=\"\" ><ul>\n<li><a href=\"http:\/\/www.mppsolar.com\/manual\/Watchpower%20(HS_MS)\/WatchPower_user_manual.pdf\"><span style=\"color: #0000ff;\">WatchPower User Manual<\/span><\/a><\/li>\n<\/ul>\n<p>**For WatchPower software please contact our Sales team <span style=\"color: #0000ff;\"><a href=\"mailto:sales@mppsolar.com\"><span style=\"color: #0000ff;\">sales@mppsolar.com<\/span><\/a><\/span> directly.<\/p>\n<\/li><\/ul>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>PIP-MS\/MSX SERIES &nbsp;<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-2139","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/2139","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/comments?post=2139"}],"version-history":[{"count":0,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/2139\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/media?parent=2139"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}