{"id":13125,"date":"2024-07-26T08:59:04","date_gmt":"2024-07-26T08:59:04","guid":{"rendered":"https:\/\/www.mppsolar.com\/v3\/?page_id=13125"},"modified":"2024-08-02T08:02:53","modified_gmt":"2024-08-02T08:02:53","slug":"mph15kwp-t","status":"publish","type":"page","link":"https:\/\/www.mppsolar.com\/v3\/mph15kwp-t\/","title":{"rendered":"MPH 15K WP-T (IP65)"},"content":{"rendered":"<hr \/>\n<ul class='tabs'><li><a data-href=\"tab-0\" class=\"gdl-title active\" >OVERVIEW<\/a><\/li><li><a data-href=\"tab-1\" class=\"gdl-title \" >FEATURES<\/a><\/li><li><a data-href=\"tab-2\" class=\"gdl-title \" >DOCUMENTATION<\/a><\/li><li><a data-href=\"tab-3\" class=\"gdl-title \" >MONITORING<\/a><\/li><li><a data-href=\"tab-4\" class=\"gdl-title \" >OPTIONAL<\/a><\/li><\/ul><ul class='tabs-content'><li data-href=\"tab-0\" class=\"active\" ><p class=\"text\">While bearing strong resemblance to the <a href=\"https:\/\/www.mppsolar.com\/v3\/mpi12-15kwwpip65\/\"><strong>MPI WP hybrids<\/strong><\/a>, the<strong>\u00a0<span style=\"color: #0000ff;\">MPH 15KW WP-T<\/span><\/strong> is a 3 phase hybrid inverter (P-P=400V, P-N=230V) with new-generation revolutionary design on the LCD interface.\u00a0 The<strong> HMI (Human Machine Interface)<\/strong> design on LCD display significantly bridge the gap between humans and machines by offering instant feedback and control to the inverter system with ease and convenience.<\/p>\n<p>The HMI LCD display simplifies the general status overview without information clutter and offers quick and intuitive interface to various system settings that are much more user-friendly than traditional layout.<\/p>\n<p>&nbsp;<\/p>\n<p class=\"text\">\u00a0<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-13142\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/08\/hmilcd1b.jpg\" alt=\"\" width=\"1486\" height=\"315\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/08\/hmilcd1b.jpg 1486w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/08\/hmilcd1b-300x64.jpg 300w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/08\/hmilcd1b-1024x217.jpg 1024w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/08\/hmilcd1b-768x163.jpg 768w\" sizes=\"auto, (max-width: 1486px) 100vw, 1486px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-13141\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/08\/hmilcd2b.jpg\" alt=\"\" width=\"1486\" height=\"316\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/08\/hmilcd2b.jpg 1486w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/08\/hmilcd2b-300x64.jpg 300w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/08\/hmilcd2b-1024x218.jpg 1024w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/08\/hmilcd2b-768x163.jpg 768w\" sizes=\"auto, (max-width: 1486px) 100vw, 1486px\" \/><\/p>\n<p>In addition to System Information and Settings, users now can also directly view energy generation graph as well as have direct access to advanced settings such as voltage and current calibration without using external tools.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-13144\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/08\/hmilcd3b.jpg\" alt=\"\" width=\"1486\" height=\"313\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/08\/hmilcd3b.jpg 1486w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/08\/hmilcd3b-300x63.jpg 300w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/08\/hmilcd3b-1024x216.jpg 1024w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/08\/hmilcd3b-768x162.jpg 768w\" sizes=\"auto, (max-width: 1486px) 100vw, 1486px\" \/><\/p>\n<p class=\"text\">Other important features include:<\/p>\n<ol>\n<li><span style=\"color: #ff0000;\"><strong>IP65 weatherproof enclosure (with IP65 design fans)<\/strong><\/span><\/li>\n<li><span style=\"color: #ff0000;\"><strong>Dual 2X AC output terminals<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>Grid interactive (grid injection) capable<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>High PV input design 1000V<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>Max charging current up to 300A<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>Dual 2X PV input<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>Built-in WIFI transmitter (monitoring on mobile phone)<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>BMS support for select battery systems<\/strong><\/span><\/li>\n<li><strong style=\"color: #0000ff;\">Parallel up to 6 units (up to 90KW)<\/strong><\/li>\n<li><strong style=\"color: #0000ff;\">VDE0126 \/ 4105 compliant<\/strong><\/li>\n<\/ol>\n<p>For more information, please download the user manual and catalog from tab page above or contact our sales office at <span style=\"color: #0000ff;\"><a href=\"mailto:sales@mppsolar.com\"><span style=\"color: #0000ff;\">sales@mppsolar.com<\/span><\/a><\/span>.<\/p>\n<p><strong>Note: MPH 15K WP-T cannot parallel with MPI hybrid inverters.\u00a0<\/strong><\/p>\n<\/li><li data-href=\"tab-1\" class=\"\" ><p style=\"color: #ff0000;\"><span style=\"color: #000000;\"><div class=\"shortcode-list shortcode-list-check\"><\/span><\/p>\n<ul>\n<li><span style=\"color: #ff0000;\"><strong>New HMI (Human Machine Interface) touchscreen LCD design<\/strong><\/span><\/li>\n<li><span style=\"color: #ff0000;\"><strong>Dual 2X AC output terminals (smart load management)<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>IP65 weatherproof enclosure (with IP65 design fans)<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>Max continuous 15KW pure sine wave output inverter<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>Grid interactive (grid injection) capable<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>Modes: Grid-Tie with Battery Backup, Grid-Tie only, Off-Grid<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>3-phase design P-P 400V, P-N 230V\u00a0<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>High PV input up to 1000VDC with dual (2X) PV input<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>Max PV array up to 22.5KW\u00a0<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>Built-in WIFI transmitter to support monitoring on smartphones<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>BMS communication for Pylontech, Soltaro and Weco battery systems<\/strong><\/span><\/li>\n<li><strong style=\"color: #0000ff;\">Parallel capable up to 6 units (90KW) with built-in parallel kits<\/strong><\/li>\n<li><strong style=\"color: #0000ff;\">Timer feature for AC output and charging\u00a0<\/strong><\/li>\n<li><strong style=\"color: #0000ff;\">VDE0126 \/ 4105 compliant<\/strong><span style=\"color: #000000;\"><br \/>\n<\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>Compatible with Modbus Card \/ Modbus Server \/ Energy Meter accessories<\/strong><\/span><\/li>\n<li><span style=\"color: #000000;\">50Hz &amp; 60Hz support<\/span><\/li>\n<li>Programmable parameters<\/li>\n<li>Adjustable bulk &amp; float charging voltage<\/li>\n<li>Genset starter dry contact<\/li>\n<li>Overload and short circuit protection<\/li>\n<li>FREE monitoring software (SolarPower)<\/li>\n<li>RS232\/USB\/BMS\/WIFI\/Dry Contact\/Intelligent Slot communication interface<\/li>\n<\/ul>\n<p><\/div><\/p>\n<div class=\"message-box-wrapper blue\"><div class=\"message-box-title\">IP65 WP Installation Guidance<\/div><div class=\"message-box-content\"><\/p>\n<ul>\n<li><strong>do NOT install units on sites where there is direct exposure to sunlight, rain, snow, &gt;95% humidity, near antenna or at altitude &gt;2km above sea level<\/strong><\/li>\n<\/ul>\n<p>\n<\/div><\/div>\n<div class=\"message-box-wrapper green\"><div class=\"message-box-title\">Using Generator as AC-Input<\/div><div class=\"message-box-content\"><\/p>\n<ul>\n<li>Generator power is recommended to be 50% larger than the inverter rating to reduce chances of overload.<\/li>\n<li>Inverter-generator is recommended due to its cleaner output than conventional generators.\u00a0 Unsuitable generator output may be rejected by the inverter.<\/li>\n<li><strong>When using generator as AC input &#8211; grid injection must be DISABLED<\/strong>.<\/li>\n<\/ul>\n<p>\n<\/div><\/div>\n<div class=\"message-box-wrapper red\"><div class=\"message-box-title\">IMPORTANT<\/div><div class=\"message-box-content\"><\/p>\n<ol>\n<li>accessories such as Energy Meter, Modbus Card, and Modbus Server are all optional and may be purchased separately to establish energy meter application.<\/li>\n<li><strong>Energy meter does not support parallel operation (load sharing)<\/strong> so when connecting multiple inverters to the energy meter, parallel function needs to be disabled.<\/li>\n<\/ol>\n<p>\n<\/div><\/div>\n<\/li><li data-href=\"tab-2\" class=\"\" ><ul>\n<li><span style=\"color: #0000ff;\"><strong><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/MPH%2015K%20WP-T.pdf\">MPH 15K WP-T Catalog PDF<\/a><\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong><a style=\"color: #0000ff;\" href=\"http:\/\/www.mppsolar.com\/manual\/MPH%20WP-T%20HYBRID\/MPH%2015K%20WP-T%20manual-20240523.pdf\">MPH 15K WP-T User Manual PDF<\/a><\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/generator%20requirement.pdf\">Generator Requirement<\/a><\/strong><\/span><\/li>\n<\/ul>\n<\/li><li data-href=\"tab-3\" class=\"\" ><ul>\n<li><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"http:\/\/www.mppsolar.com\/manual\/SolarPower%20%28hybrid%29\/manual\/solarpowermanual.pdf\">SolarPower Manual (desktop)<\/a><\/span><\/strong><\/li>\n<li><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"http:\/\/www.mppsolar.com\/manual\/ACCESSORIES%20%28FOR%20MONITORING%29\/WIFI%20MODULE\/WIFI%20APP%20-%20i.Solar%20SOP%2020240103.pdf\">i.Solar (APP)<\/a><\/span><\/strong><\/li>\n<\/ul>\n<\/li><li data-href=\"tab-4\" class=\"\" ><p>These optional accessories may be sourced separately to fulfill &#8220;zero grid injection&#8221;.\u00a0 \u00a0Note &#8211; when using energy meter, the inverter must be programmed in <strong>Grid-Tie with Backup II<\/strong> mode and this also works only in single-unit operation, not parallel.<\/p>\n<p><a href=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/02\/energymeter.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-12958\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/02\/energymeter.jpg\" alt=\"\" width=\"450\" height=\"554\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/02\/energymeter.jpg 1120w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/02\/energymeter-243x300.jpg 243w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/02\/energymeter-831x1024.jpg 831w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/02\/energymeter-768x946.jpg 768w\" sizes=\"auto, (max-width: 450px) 100vw, 450px\" \/><\/a><\/p>\n<ul>\n<li><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"http:\/\/www.mppsolar.com\/manual\/ACCESSORIES%20(FOR%20MONITORING)\/MODBUS,%20ENERGY%20METER\/(hybrid)%20Modbus%20card%20II%20energy%20meter-manual_20150505.pdf\">Modbus Card<\/a><\/span><\/strong><\/li>\n<li><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"http:\/\/www.mppsolar.com\/manual\/ACCESSORIES%20(FOR%20MONITORING)\/MODBUS,%20ENERGY%20METER\/(hybrid)%20Modbus%20server%20for%20energy%20meter-Quick%20Guide_20141001.pdf\">Modbus Server for Energy Meter<\/a><\/span><\/strong><\/li>\n<li><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"http:\/\/www.mppsolar.com\/manual\/ACCESSORIES%20(FOR%20MONITORING)\/MODBUS,%20ENERGY%20METER\/Energy-Meter_manual-20161221.pdf\">Energy Meter<\/a><\/span><\/strong><\/li>\n<\/ul>\n<\/li><\/ul>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-13125","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/13125","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/comments?post=13125"}],"version-history":[{"count":8,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/13125\/revisions"}],"predecessor-version":[{"id":13145,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/13125\/revisions\/13145"}],"wp:attachment":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/media?parent=13125"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}