{"id":13027,"date":"2024-04-11T06:40:29","date_gmt":"2024-04-11T06:40:29","guid":{"rendered":"https:\/\/www.mppsolar.com\/v3\/?page_id=13027"},"modified":"2025-02-13T06:52:39","modified_gmt":"2025-02-13T06:52:39","slug":"3024lv-msd","status":"publish","type":"page","link":"https:\/\/www.mppsolar.com\/v3\/3024lv-msd\/","title":{"rendered":"SPLIT PHASE &#8211; 3024LV-MSD"},"content":{"rendered":"<ul class='tabs'><li><a data-href=\"tab-0\" class=\"gdl-title active\" >OVERVIEW<\/a><\/li><li><a data-href=\"tab-1\" class=\"gdl-title \" >FEATURES<\/a><\/li><li><a data-href=\"tab-2\" class=\"gdl-title \" >Documentation<\/a><\/li><li><a data-href=\"tab-3\" class=\"gdl-title \" >MONITORING<\/a><\/li><\/ul><ul class='tabs-content'><li data-href=\"tab-0\" class=\"active\" ><p style=\"color: #0000ff;\"><span style=\"color: #000000;\">The <\/span><span style=\"color: #000000;\"><span style=\"color: #0000ff;\"><b>3024LV-MSD\u00a0<\/b><span style=\"color: #000000;\">is a new LV model derived from its predecessor (2424LV-MSD, 120VAC output) with the following 6 new upgraded feature:<\/span><\/span><\/span><\/p>\n<div class=\"shortcode-list shortcode-list-check\"><\/p>\n<ul>\n<li><strong>High PV input design <span style=\"color: #ff0000;\">250V (Voc)<\/span><\/strong><\/li>\n<li><strong>Parallel support now <span style=\"color: #ff0000;\">up to 9 units<\/span><\/strong><\/li>\n<li><strong>Split phase support <span style=\"color: #ff0000;\">120\/240VAC, via parallel (3P 208V also supported)<\/span><\/strong><\/li>\n<li><strong>Batteryless design <span style=\"color: #ff0000;\">battery optional<\/span><\/strong><\/li>\n<li><strong>Built-in <span style=\"color: #ff0000;\">parallel kit<\/span><\/strong><\/li>\n<li><strong>BMS port <span style=\"color: #ff0000;\">lithium battery communication*<\/span><\/strong><\/li>\n<li><strong>Built-in <span style=\"color: #ff0000;\">WIFI (new)<\/span><\/strong><\/li>\n<\/ul>\n<p><\/div>\n<p><span style=\"color: #000000;\">Similar to the <a href=\"https:\/\/www.mppsolar.com\/v3\/split-phase-lv\/\">LV2424<\/a> and <a href=\"https:\/\/www.mppsolar.com\/v3\/lv-mk\/\">3048LV-MK<\/a>, the <span style=\"color: #0000ff;\"><b>3024LV-MSD<\/b><\/span> is also a 120V output inverter alone but can parallel into<strong> split phase output (120V\/240V)<\/strong> with 2 units or more.\u00a0 Also, <\/span><span style=\"color: #000000;\">parallel configuration comes in 3 types: <strong>single phase (120VAC), 3-phase (120\/208VAC), or split phase (120V\/240V)<\/strong>.\u00a0<\/span><\/p>\n<div class=\"message-box-wrapper red\"><div class=\"message-box-title\">Important note about Batteryless Operation<\/div><div class=\"message-box-content\"><p>When configuring system in parallel using multiple units, please be sure that a battery <strong>MUST <\/strong>be used or otherwise it may cause system to work incorrectly, or possibly lead to damage.\u00a0 Failure caused by the lack of a battery is considered as an installation error and will not be covered under warranty<\/p>\n<\/div><\/div>\n<p style=\"color: #0000ff;\"><span style=\"color: #000000;\">For more information, please download the catalogs at the tab page above or contact our sales office at<\/span> <span style=\"color: #0000ff;\"><a href=\"mailto:sales@mppsolar.com\">sales@mppsolar.com<\/a><\/span>.<\/p>\n<p><span style=\"color: #808080;\">*BMS cable required (optional accessory)<\/span><\/p>\n<\/li><li data-href=\"tab-1\" class=\"\" ><div class=\"shortcode-list shortcode-list-check\"><\/p>\n<ul>\n<li><strong><span style=\"color: #0000ff;\">Max 3KW \/ 24VDC pure sine wave output 120V<\/span><\/strong><\/li>\n<li><strong><span style=\"color: #0000ff;\">Parallel support up to 9 units, in single phase (120V), split phase (120V\/240V\/208V) or 3-phase (208V)<\/span><\/strong><\/li>\n<li><strong><span style=\"color: #0000ff;\">Max PV input up to 250V<\/span><\/strong><\/li>\n<li><strong><span style=\"color: #0000ff;\">Built-in parallel kit + WIFI transmitter<\/span><\/strong><\/li>\n<li><strong><span style=\"color: #0000ff;\">Batteryless operation (single unit mode only)<\/span><\/strong><\/li>\n<li><strong><span style=\"color: #0000ff;\">Pylontech\/Weco\/Soltaro Lithium BMS support*<\/span><\/strong><\/li>\n<li><span style=\"color: #000000;\">Equalization Charge<\/span><\/li>\n<li>Built-in MPPT solar charger max 80A<\/li>\n<li>Built-in utility battery charger max 80A<\/li>\n<li>Comprehensive programming options<\/li>\n<li>BMS + RS232 communication ports<\/li>\n<li>Indoor installation only<\/li>\n<li>Wide AC input range for bypass<\/li>\n<li><span style=\"color: #000000;\">FREE bundled monitoring software on PC<\/span><\/li>\n<\/ul>\n<p><\/div>\n<p><span style=\"color: #808080;\">*BMS cable required (optional accessory)<br \/>\n<\/span><\/p>\n<div class=\"message-box-wrapper red\"><div class=\"message-box-title\">Using Generator as AC-Input<\/div><div class=\"message-box-content\"><\/p>\n<ul>\n<li>Generator power is recommended to be 50% larger than the inverter rating to reduce chances of overload.<\/li>\n<li>Inverter-generator is recommended due to its cleaner output than conventional generators.\u00a0 Unsuitable generator output may be rejected by the inverter.<\/li>\n<\/ul>\n<p>\n<\/div><\/div>\n<\/li><li data-href=\"tab-2\" class=\"\" ><ul>\n<li><strong><a href=\"http:\/\/www.mppsolar.com\/v3\/catalogs\/3024LV-MSD.pdf\"><span style=\"color: #0000ff;\">Product Catalog<\/span><\/a><\/strong><\/li>\n<li><strong><a href=\"http:\/\/www.mppsolar.com\/manual\/SPLIT%20PHASE%20LV\/3024LV-MSD-manual-20241015.pdf\"><span style=\"color: #0000ff;\">User Manual<\/span><\/a><\/strong><\/li>\n<li><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/generator%20requirement.pdf\">Generator Requirement<\/a><\/span><\/strong><\/li>\n<\/ul>\n<\/li><li data-href=\"tab-3\" class=\"\" ><ul>\n<li><strong><a href=\"http:\/\/www.mppsolar.com\/manual\/Watchpower%20(off-grid)\/WatchPower%20user%20manual.pdf\"><span style=\"color: #0000ff;\">WatchPower User Manual<\/span><\/a><\/strong><\/li>\n<\/ul>\n<\/li><\/ul>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-13027","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/13027","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/comments?post=13027"}],"version-history":[{"count":5,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/13027\/revisions"}],"predecessor-version":[{"id":13258,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/13027\/revisions\/13258"}],"wp:attachment":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/media?parent=13027"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}