{"id":12821,"date":"2023-09-20T07:11:05","date_gmt":"2023-09-20T07:11:05","guid":{"rendered":"https:\/\/www.mppsolar.com\/v3\/?page_id=12821"},"modified":"2025-08-27T07:40:35","modified_gmt":"2025-08-27T07:40:35","slug":"lvx12kwwp","status":"publish","type":"page","link":"https:\/\/www.mppsolar.com\/v3\/lvx12kwwp\/","title":{"rendered":"SPLIT PHASE HYBRID &#8211; LVX 12KW WP"},"content":{"rendered":"<ul class='tabs'><li><a data-href=\"tab-0\" class=\"gdl-title active\" >OVERVIEW<\/a><\/li><li><a data-href=\"tab-1\" class=\"gdl-title \" >FEATURES<\/a><\/li><li><a data-href=\"tab-2\" class=\"gdl-title \" >DOCUMENTATION<\/a><\/li><li><a data-href=\"tab-3\" class=\"gdl-title \" >MONITORING<\/a><\/li><\/ul><ul class='tabs-content'><li data-href=\"tab-0\" class=\"active\" ><p class=\"text\"><span style=\"color: #0000ff;\"><strong>LVX 12KW WP<\/strong><\/span> is a brand new split phase hybrid (grid-interactive) inverter developed based on new construction procedure, specifically to target the rising power demand of users in the 120\/240V split phase North American market.\u00a0 Featuring max <span style=\"color: #0000ff;\"><strong>12KW PV array<\/strong><\/span> support, this model can deliver up to <span style=\"color: #0000ff;\"><strong>10KW<\/strong><\/span> of maximum continuous power and up to <strong><span style=\"color: #0000ff;\">15KW with grid-relay function enabled<\/span><\/strong>.\u00a0 \u00a0In addition to UL1741 and CSA certifications for North America, <a href=\"https:\/\/solarequipment.energy.ca.gov\/Home\/InvertersList?ManufacturerID=MPP+SOLAR+INC&amp;ModelNameID=-1&amp;Submit=Search&amp;Rows=25\"><span style=\"text-decoration: underline;\"><strong>we are also pleased to announce LVX 12K WP is now CEC listed (California Energy Commission)<\/strong><\/span><\/a>.\u00a0 Benefits of being CEC listed allows customers to qualify for applicable Federal rebate \/ credit \/ loan.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-13199\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/10\/CEC.png\" alt=\"\" width=\"1530\" height=\"566\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/10\/CEC.png 1530w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/10\/CEC-300x111.png 300w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/10\/CEC-1024x379.png 1024w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/10\/CEC-768x284.png 768w\" sizes=\"auto, (max-width: 1530px) 100vw, 1530px\" \/><\/p>\n<p>Other notable features of this promising model include:<\/p>\n<ol>\n<li><strong><span style=\"color: #ff0000;\">(OPTIONAL) AC coupling with existing GT systems<\/span><\/strong><\/li>\n<li><span style=\"color: #0000ff;\"><strong>IP65 weatherproof enclosure (with IP65 design fans)<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>Dual AC input ports &#8212; utility + generator<\/strong><\/span><\/li>\n<li><strong><span style=\"color: #0000ff;\">Zero grid injection with CT (standard accessory)<\/span><\/strong><\/li>\n<li><span style=\"color: #0000ff;\"><strong>Grid-relay feature boosts max output up to 14KW<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>New monitoring app (i.Solar) with OTA firmware feature<\/strong><\/span><\/li>\n<li><span style=\"color: #000000;\"><strong>120\/240V split phase output ready<\/strong><\/span><\/li>\n<li><span style=\"color: #000000;\"><strong>Grid interactive (grid injection) capable<\/strong><\/span><\/li>\n<li><span style=\"color: #000000;\"><strong>High PV input design (600V) with dual (2X) PV input<\/strong><\/span><\/li>\n<li><span style=\"color: #000000;\"><strong>Built-in WIFI transmitter for monitoring on smartphones<\/strong><\/span><\/li>\n<li><span style=\"color: #000000;\"><strong>BMS communication for Pylontech, Soltaro and Weco battery systems<\/strong><\/span><\/li>\n<li><span style=\"color: #000000;\"><strong>Battery optional &#8211; use PV panels straight to load<\/strong><\/span><\/li>\n<li><span style=\"color: #000000;\"><strong>Parallel capable up to 6 units (60KW) with built-in parallel kits<\/strong><\/span><\/li>\n<li><span style=\"color: #000000;\"><strong>Timer feature for AC output and charging<\/strong><\/span><\/li>\n<li><span style=\"color: #000000;\"><strong>UL1741\/CSA compliant<\/strong><\/span><\/li>\n<\/ol>\n<p class=\"text\">An important feature for a hybrid inverter is the ability to fulfill &#8220;<strong><span style=\"color: #0000ff;\">zero grid injection<\/span><\/strong>&#8220;.\u00a0 \u00a0LVX 12KW WP is able to achieve this with the use of CT sensors (standard accessory) and once this feature is activated, the inverter will direct all incoming PV energy for self-consumption, as illustrated below.\u00a0 Note: each CT is rated for 50A and should be installed on each phase and this setup is applicable for one inverter at this time. Larger CTs will be required for multiple units in parallel.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-12820\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2023\/09\/lvx12kwwp-3.jpg\" alt=\"\" width=\"1417\" height=\"590\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2023\/09\/lvx12kwwp-3.jpg 1417w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2023\/09\/lvx12kwwp-3-300x125.jpg 300w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2023\/09\/lvx12kwwp-3-1024x426.jpg 1024w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2023\/09\/lvx12kwwp-3-768x320.jpg 768w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2023\/09\/lvx12kwwp-3-900x375.jpg 900w\" sizes=\"auto, (max-width: 1417px) 100vw, 1417px\" \/><\/p>\n<p>Similar to the MPI Hybrid series (<span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/mpi-hybrid-series-2\/\">MPI 10K<\/a><\/span>, <span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/mpi12-15kwwpip65\/\">MPI 12K\/15K WP<\/a><\/span>)\uff0cthis model also retains Grid Relay feature and will increase maximum power capacity from 10KW to 15KW (5KW power boost from grid) when this feature is enabled.\u00a0 \u00a0For more details on this please refer to catalog &amp; user manual.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-13300\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2025\/08\/lvx12kwwp-5b.jpg\" alt=\"\" width=\"1417\" height=\"590\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2025\/08\/lvx12kwwp-5b.jpg 1417w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2025\/08\/lvx12kwwp-5b-300x125.jpg 300w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2025\/08\/lvx12kwwp-5b-1024x426.jpg 1024w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2025\/08\/lvx12kwwp-5b-768x320.jpg 768w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2025\/08\/lvx12kwwp-5b-900x375.jpg 900w\" sizes=\"auto, (max-width: 1417px) 100vw, 1417px\" \/><\/p>\n<p>Unique to the LVX 12KW WP, the ability to <span style=\"color: #0000ff;\"><strong>AC couple<\/strong><\/span> with existing grid-tie inverter which allows users to transform existing home RE system with greater flexibility, battery backup, and better utility of PV array.\u00a0 Note: <span style=\"text-decoration: underline;\">this is an OPTIONAL feature<\/span> and will require firmware update and setting and wiring change in order to fulfill application.\u00a0 For more information, please refer to product catalog \/ AC coupling manual or contact our Sales Team directly.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-13180\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/09\/lvx12kwwp-9.jpg\" alt=\"\" width=\"1417\" height=\"590\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/09\/lvx12kwwp-9.jpg 1417w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/09\/lvx12kwwp-9-300x125.jpg 300w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/09\/lvx12kwwp-9-1024x426.jpg 1024w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/09\/lvx12kwwp-9-768x320.jpg 768w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/09\/lvx12kwwp-9-900x375.jpg 900w\" sizes=\"auto, (max-width: 1417px) 100vw, 1417px\" \/><\/p>\n<p>*For sample orders and distribution inquiry, please contact our sales team at <span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"mailto:sales@mppsolar.com\">sales@mppsolar.com<\/a><\/span>.<\/p>\n<\/li><li data-href=\"tab-1\" class=\"\" ><div class=\"message-box-wrapper red\"><div class=\"message-box-title\">IP65 WP Installation Guidance<\/div><div class=\"message-box-content\"><\/p>\n<ul>\n<li><strong>WARNING: please do NOT install units on sites where there is direct exposure to sunlight, rain, snow, &gt;95% humidity, near antenna or at altitude &gt;2km above sea level<\/strong><\/li>\n<\/ul>\n<p>\n<\/div><\/div>\n<div class=\"message-box-wrapper blue\"><div class=\"message-box-title\">Using Generator as AC-Input<\/div><div class=\"message-box-content\"><\/p>\n<ul>\n<li>Generator power is recommended to be 50% larger than the inverter rating to reduce chances of overload and inverter-generator type is recommended for its cleaner output than conventional generators.\u00a0 Unsuitable generator output will be rejected by the inverter. \u00a0<a href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/generator%20requirement.pdf\"><span style=\"color: #0000ff;\">See guide<\/span><\/a>.<\/li>\n<li>Generator port will be automatically disabled when grid is available or when inverter is set up for parallel.<\/li>\n<\/ul>\n<p>\n<\/div><\/div>\n<div class=\"message-box-wrapper yellow\"><div class=\"message-box-title\">Grid Relay<\/div><div class=\"message-box-content\"><\/p>\n<ul>\n<li>Additional power boost may be achieved at AC output by activating &#8220;grid-relay&#8221; feature on the inverter, <strong>available only in Off-Grid modes I and II via setting in SolarPowe<\/strong>r.\u00a0 Grid injection will be disabled when off-grid modes are selected.<\/li>\n<\/ul>\n<p>\n<\/div><\/div>\n<p style=\"color: #ff0000;\"><span style=\"color: #000000;\"><div class=\"shortcode-list shortcode-list-check\">.<\/span><\/p>\n<ul>\n<li><strong><span style=\"color: #ff0000;\">(OPTIONAL) AC coupling with existing GT systems<\/span><\/strong><\/li>\n<li><span style=\"color: #ff0000;\"><strong>UL1741 &amp; CSA compliant \/ CEC listed<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>IP65 weatherproof enclosure (with IP65 design fans)<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>Dual AC input ports &#8212; utility + generator<\/strong><\/span><\/li>\n<li><strong><span style=\"color: #0000ff;\">Zero grid injection with CT (standard accessory, 2 pieces included with inverter)<\/span><\/strong><\/li>\n<li><span style=\"color: #0000ff;\"><strong>Grid-relay feature boosts max output up to 14KW<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>New monitoring APP (i.Solar) with OTA firmware feature<\/strong><\/span><\/li>\n<li><strong>Pure sine wave maximum continuous output 10KW<\/strong><\/li>\n<li><strong>Maximum PV array power 12KW<\/strong><\/li>\n<li><strong>120\/240V split phase ready<\/strong><\/li>\n<li><strong>Grid interactive (grid injection) capable<\/strong><\/li>\n<li><strong>High PV input design (600V) with dual (2X) PV input<\/strong><\/li>\n<li><strong>Maximum charging current 200A (solar, AC, or combined)<\/strong><\/li>\n<li><strong>Built-in WIFI transmitter to support monitoring on smartphones<\/strong><\/li>\n<li><strong>BMS RS485 + CANbus communication support for BMS (with pre-defined support for Pylontech, Soltaro and Weco BMS)<\/strong><\/li>\n<li><strong>Battery optional &#8211; use PV to power load directly without battery<\/strong><\/li>\n<li><strong>Parallel capable up to 6 units (60KW) with built-in parallel kits<\/strong><\/li>\n<li><strong>50Hz &amp; 60Hz support<\/strong><\/li>\n<li><strong>Timer feature for AC output and charging<\/strong><\/li>\n<li><strong>Large LCD touchscreen<\/strong><\/li>\n<li><strong>Programmable parameters<\/strong><\/li>\n<li><strong>Genset starter dry contact<\/strong><\/li>\n<li><strong>FREE monitoring software on PC &amp; Mac<\/strong><\/li>\n<li><strong>RS232\/USB\/BMS\/WIFI\/dry contact communication interface<\/strong><\/li>\n<\/ul>\n<p><\/div><\/p>\n<\/li><li data-href=\"tab-2\" class=\"\" ><ul>\n<li><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"http:\/\/www.mppsolar.com\/v3\/catalogs\/LVX12KWP.pdf\">LVX 12KW WP Catalog PDF<\/a><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/mppsolar.com\/manual\/SPLIT%20PHASE%20LV\/LVX%2012KW%20WP%20manual-20250306.pdf\">LVX 12KW WP User Manual PDF<\/a><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/mppsolar.com\/manual\/SPLIT%20PHASE%20LV\/Appendix%20V%20AC%20coupling%20%20LVX%2012KW%20WP%20manual.pdf\">AC Coupling Manual PDF<\/a><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/mppsolar.com\/manual\/SPLIT%20PHASE%20LV\/OTA%20Wi-Fi%20Firmware%20Upgrade%20Operation%20Guide%20for%20Inverter%2020240126.pdf\">OTA Wifi Update Guide PDF<\/a><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/generator%20requirement.pdf\">Generator Requirement<\/a><\/span><\/li>\n<\/ul>\n<\/li><li data-href=\"tab-3\" class=\"\" ><ul>\n<li><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"http:\/\/www.mppsolar.com\/manual\/SolarPower%20%28hybrid%29\/manual\/solarpowermanual.pdf\">SolarPower Manual<\/a> (PC)<\/span><\/li>\n<li><a href=\"http:\/\/www.mppsolar.com\/manual\/ACCESSORIES%20%28FOR%20MONITORING%29\/WIFI%20MODULE\/WIFI%20APP%20-%20i.Solar%20SOP%2020240103.pdf\"><span style=\"color: #0000ff;\">i.Solar APP Manual (Smartphone)<\/span><\/a><\/li>\n<\/ul>\n<p>**For SolarPower software please visit our <span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/download\/\">Download<\/a> <\/span>page.<\/p>\n<\/li><\/ul>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-12821","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/12821","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/comments?post=12821"}],"version-history":[{"count":5,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/12821\/revisions"}],"predecessor-version":[{"id":13301,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/12821\/revisions\/13301"}],"wp:attachment":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/media?parent=12821"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}