{"id":11883,"date":"2022-03-27T04:04:36","date_gmt":"2022-03-27T04:04:36","guid":{"rendered":"https:\/\/www.mppsolar.com\/v3\/?page_id=11883"},"modified":"2024-03-25T03:29:48","modified_gmt":"2024-03-25T03:29:48","slug":"mpi12-15kwwpip65","status":"publish","type":"page","link":"https:\/\/www.mppsolar.com\/v3\/mpi12-15kwwpip65\/","title":{"rendered":"MPI 12KW, 15KW WP (IP65)"},"content":{"rendered":"<hr \/>\n<ul class='tabs'><li><a data-href=\"tab-0\" class=\"gdl-title active\" >OVERVIEW<\/a><\/li><li><a data-href=\"tab-1\" class=\"gdl-title \" >FEATURES<\/a><\/li><li><a data-href=\"tab-2\" class=\"gdl-title \" >DOCUMENTATION<\/a><\/li><li><a data-href=\"tab-3\" class=\"gdl-title \" >MONITORING<\/a><\/li><li><a data-href=\"tab-4\" class=\"gdl-title \" >OPTIONAL<\/a><\/li><\/ul><ul class='tabs-content'><li data-href=\"tab-0\" class=\"active\" ><p class=\"text\">Available in 12KW and 15KW output, the <strong>MPI 12KW\/15KW WP<\/strong> is the latest IP65 model to MPP Solar Hybrid family.\u00a0 Maximum PV array support now is 16KW on both models and max charging current is up to 300A (MPI 15KW WP). Similar to the <span style=\"color: #0000ff;\"><strong><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/mpi-hybrid-series-2\/\">MPI 10K<\/a><\/strong><\/span> , they also offer 3 primary modes:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-11892 aligncenter\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2022\/03\/mpiwpmodes.png\" alt=\"\" width=\"696\" height=\"805\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2022\/03\/mpiwpmodes.png 696w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2022\/03\/mpiwpmodes-259x300.png 259w\" sizes=\"auto, (max-width: 696px) 100vw, 696px\" \/><\/p>\n<p class=\"text\">Other important features include:<\/p>\n<ol>\n<li><span style=\"color: #ff0000;\"><strong>IP65 weatherproof enclosure (with IP65 design fans)<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>3-Phase 400VAC output (p-p)<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>Grid interactive (grid injection) capable<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>High PV input design 1000V<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>Dual 2X PV input<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>Built-in WIFI transmitter (monitoring on mobile phone)<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>BMS support for Pylontech, Soltaro and Weco battery systems<\/strong><\/span><\/li>\n<li><strong style=\"color: #0000ff;\">Parallel up to 6 units (up to 90KW)<\/strong><\/li>\n<li><strong style=\"color: #0000ff;\">VDE compliant<\/strong><\/li>\n<\/ol>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-11887\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2022\/03\/mpi12k15k4.jpg\" alt=\"\" width=\"1417\" height=\"591\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2022\/03\/mpi12k15k4.jpg 1417w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2022\/03\/mpi12k15k4-300x125.jpg 300w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2022\/03\/mpi12k15k4-1024x427.jpg 1024w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2022\/03\/mpi12k15k4-768x320.jpg 768w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2022\/03\/mpi12k15k4-600x250.jpg 600w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2022\/03\/mpi12k15k4-900x375.jpg 900w\" sizes=\"auto, (max-width: 1417px) 100vw, 1417px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-11888\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2022\/03\/mpi12k15k3.jpg\" alt=\"\" width=\"1417\" height=\"591\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2022\/03\/mpi12k15k3.jpg 1417w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2022\/03\/mpi12k15k3-300x125.jpg 300w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2022\/03\/mpi12k15k3-1024x427.jpg 1024w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2022\/03\/mpi12k15k3-768x320.jpg 768w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2022\/03\/mpi12k15k3-600x250.jpg 600w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2022\/03\/mpi12k15k3-900x375.jpg 900w\" sizes=\"auto, (max-width: 1417px) 100vw, 1417px\" \/><\/p>\n<p>For more information, please download the user manual and catalog from tab page above or contact our sales office at <span style=\"color: #0000ff;\"><a href=\"mailto:sales@mppsolar.com\"><span style=\"color: #0000ff;\">sales@mppsolar.com<\/span><\/a><\/span>.<\/p>\n<\/li><li data-href=\"tab-1\" class=\"\" ><p style=\"color: #ff0000;\"><span style=\"color: #000000;\"><div class=\"shortcode-list shortcode-list-check\"><\/span><\/p>\n<ul>\n<li><span style=\"color: #ff0000;\"><strong>IP65 weatherproof enclosure (with IP65 design fans)<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>Grid interactive (grid injection) capable<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>3 Modes: Grid-Tie with Battery Backup, Grid-Tie only, Off-Grid<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>Pure sine wave output 12KW\/15KW<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>3-phase 400VAC output (phase to phase)<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>High PV input design (1000V) with dual (2X) PV input<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>Max PV array up to 22.5KW (MPI 15KW)<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>Built-in WIFI transmitter to support monitoring on smartphones<\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>BMS communication for Pylontech, Soltaro and Weco battery systems<\/strong><\/span><\/li>\n<li><strong style=\"color: #0000ff;\">Parallel capable up to 6 units (72KW\/90KW) with built-in parallel kits<\/strong><\/li>\n<li><strong style=\"color: #0000ff;\">Timer feature for AC output and charging vis SolarPower<\/strong><\/li>\n<li><strong style=\"color: #0000ff;\">Large LCD touchscreen<\/strong><\/li>\n<li><strong style=\"color: #0000ff;\">VDE compliant<\/strong><span style=\"color: #000000;\"><br \/>\n<\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong>Compatible with Modbus Card \/ Modbus Server \/ Energy Meter accessories<\/strong><\/span><\/li>\n<li><span style=\"color: #000000;\">50Hz &amp; 60Hz support<\/span><\/li>\n<li>Programmable parameters<\/li>\n<li>Adjustable bulk &amp; float charging voltage<\/li>\n<li>Genset starter dry contact<\/li>\n<li>Overload and short circuit protection<\/li>\n<li>FREE monitoring software<\/li>\n<li>RS232\/USB\/BMS\/WIFI\/Dry Contact\/Intelligent Slot communication interface<\/li>\n<\/ul>\n<p><\/div><\/p>\n<div class=\"message-box-wrapper blue\"><div class=\"message-box-title\">IP65 WP Installation Guidance<\/div><div class=\"message-box-content\"><\/p>\n<ul>\n<li><strong>do NOT install units on sites where there is direct exposure to sunlight, rain, snow, &gt;95% humidity, near antenna or at altitude &gt;2km above sea level<\/strong><\/li>\n<\/ul>\n<p>\n<\/div><\/div>\n<div class=\"message-box-wrapper green\"><div class=\"message-box-title\">Using Generator as AC-Input<\/div><div class=\"message-box-content\"><\/p>\n<ul>\n<li>Generator power is recommended to be 50% larger than the inverter rating to reduce chances of overload.<\/li>\n<li>Inverter-generator is recommended due to its cleaner output than conventional generators.\u00a0 Unsuitable generator output may be rejected by the inverter.<\/li>\n<li><strong>When using generator as AC input &#8211; grid injection must be DISABLED<\/strong>.<\/li>\n<\/ul>\n<p>\n<\/div><\/div>\n<div class=\"message-box-wrapper red\"><div class=\"message-box-title\">IMPORTANT<\/div><div class=\"message-box-content\"><\/p>\n<ol>\n<li>accessories such as Energy Meter, Modbus Card, and Modbus Server are all optional and may be purchased separately to establish energy meter application.<\/li>\n<li><strong>Energy meter does not support parallel operation (load sharing)<\/strong> so when connecting multiple inverters to the energy meter, parallel function needs to be disabled.<\/li>\n<\/ol>\n<p>\n<\/div><\/div>\n<\/li><li data-href=\"tab-2\" class=\"\" ><ul>\n<li><span style=\"color: #0000ff;\"><strong><a style=\"color: #0000ff;\" href=\"http:\/\/www.mppsolar.com\/v3\/catalogs\/MPI%20WP%2012-15K.pdf\">MPI 12KW\/15KW WP Catalog PDF<\/a><\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong><a style=\"color: #0000ff;\" href=\"http:\/\/www.mppsolar.com\/manual\/MPI%20WP%20HYBRID\/MPI%20WP%2012-15KW-manual%20v1.4.pdf\">MPI 12KW\/15KW WP User Manual PDF<\/a><\/strong><\/span><\/li>\n<li><span style=\"color: #0000ff;\"><strong><a style=\"color: #0000ff;\" href=\"https:\/\/www.mppsolar.com\/v3\/catalogs\/generator%20requirement.pdf\">Generator Requirement<\/a><\/strong><\/span><\/li>\n<\/ul>\n<\/li><li data-href=\"tab-3\" class=\"\" ><ul>\n<li><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"http:\/\/www.mppsolar.com\/manual\/SolarPower%20%28hybrid%29\/manual\/solarpowermanual.pdf\">SolarPower Manual (desktop)<\/a><\/span><\/strong><\/li>\n<li><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"http:\/\/www.mppsolar.com\/manual\/ACCESSORIES%20%28FOR%20MONITORING%29\/WIFI%20MODULE\/Energy-Mate%20APP%20User%20Manual-20230628.pdf\">Energy Mate (APP)<\/a><\/span><\/strong><\/li>\n<\/ul>\n<\/li><li data-href=\"tab-4\" class=\"\" ><p>These optional accessories may be sourced separately to fulfill &#8220;zero grid injection&#8221;.\u00a0 \u00a0Note &#8211; when using energy meter, the inverter must be programmed in <strong>Grid-Tie with Backup II<\/strong> mode and this also works only in single-unit operation, not parallel.<\/p>\n<p><a href=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/02\/energymeter.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-12958\" src=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/02\/energymeter.jpg\" alt=\"\" width=\"450\" height=\"554\" srcset=\"https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/02\/energymeter.jpg 1120w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/02\/energymeter-243x300.jpg 243w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/02\/energymeter-831x1024.jpg 831w, https:\/\/www.mppsolar.com\/v3\/wp-content\/uploads\/2024\/02\/energymeter-768x946.jpg 768w\" sizes=\"auto, (max-width: 450px) 100vw, 450px\" \/><\/a><\/p>\n<ul>\n<li><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"http:\/\/www.mppsolar.com\/manual\/ACCESSORIES%20(FOR%20MONITORING)\/MODBUS,%20ENERGY%20METER\/(hybrid)%20Modbus%20card%20II%20energy%20meter-manual_20150505.pdf\">Modbus Card<\/a><\/span><\/strong><\/li>\n<li><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"http:\/\/www.mppsolar.com\/manual\/ACCESSORIES%20(FOR%20MONITORING)\/MODBUS,%20ENERGY%20METER\/(hybrid)%20Modbus%20server%20for%20energy%20meter-Quick%20Guide_20141001.pdf\">Modbus Server for Energy Meter<\/a><\/span><\/strong><\/li>\n<li><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"http:\/\/www.mppsolar.com\/manual\/ACCESSORIES%20(FOR%20MONITORING)\/MODBUS,%20ENERGY%20METER\/Energy-Meter_manual-20161221.pdf\">Energy Meter<\/a><\/span><\/strong><\/li>\n<\/ul>\n<\/li><\/ul>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-11883","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/11883","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/comments?post=11883"}],"version-history":[{"count":13,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/11883\/revisions"}],"predecessor-version":[{"id":12181,"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/pages\/11883\/revisions\/12181"}],"wp:attachment":[{"href":"https:\/\/www.mppsolar.com\/v3\/wp-json\/wp\/v2\/media?parent=11883"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}